English INSTALLATION

5.3.4  Installing an external frequency converter

Fig. 4: 

Description 

1

Inlet

3

Direction of flow arrow

2

Pressure connection

The frequency converter is installed directly in 

the piping so that it is cooled by the fluid being 

pumped during operation.

Note:

• 

Ambient conditions:

• 

Ambient temperature: 4...40 °C (frost-proof)

• 

Fluid temperature: 3...35 °C

• 

Protection class: IPX5 (overflow-proof instal

-

lation).

• The electrical connection and all settings are 

carried out on the frequency converter itself. It 
therefore needs to be easily accessible.

• 

During installation, note the direction of flow. 
See the direction of flow arrow on the frequency 

converter's housing.

NOTE:

 

The pressure and inlet connection on the 

frequency converter is sized 

G 1

1/4

, the pres-

sure connection on the pump is sized 

Rp 1

 for 

version TWU 3-05..-ECP 

Rp 1¼

. Depending on 

the discharge pipeline, 

1 or 2 adaptors

 need 

to be installed downstream of the frequency 
converter by the customer.

5.4  Dry-running protection

Submersible pumps are cooled by the fluid. 

Therefore, the motor must always be immersed. 
In addition, make sure that no air enters the 
hydraulics housing. The pump must therefore al-

ways be immersed in the fluid up to the top edge 

of the hydraulic housing. For optimum operational 
reliability, we recommend installing a dry-running 
protection system.

The TWU 3-...-HS has a built-in dry-running pro

-

tection in the frequency converter. If the water 

level fluctuates strongly, the motor's maximum 

switching cycles may be exceeded. This could 
lead to overheating of the motor. In this case, we 
therefore recommend an additional dry-running 
protection provided by the customer.
Dry-running protection is provided with the help 
of electrodes or level sensors. The signal trans-

mitter is fixed in the borehole/basin and switches 

off the pump when the water level falls below the 
minimum water submersion.

5.4.1  Remedies for avoiding excessive switching 

cycles

Manual reset – the motor is switched off when 
the water level falls below the minimum cover-

age level and switched back on when a sufficient 

water level is reached.
Separate reactivation point – a second switch-
ing point (additional electrode) is used to obtain 

a sufficient difference between the activation 

and deactivation points. This prevents constant 
switching. This function can be put into effect 
with a level control relay.

5.5  Electrical connection

RISK of death due to electrocution! 

Incorrect electrical connections can cause fa-

tal electric shocks. Electrical connections may 

only be carried out by a qualified electrician 

approved by the local energy supply company, 

in accordance with locally applicable regula-

tions.

• The mains connection current and voltage must 

be as stated on the rating plate.

• Connect the power supply cable in accordance 

with the applicable standards and regulations and 
according to the conductor assignment.

• Any available monitoring equipment must be 

connected and tested to ensure that it is working 
properly.

• Earth the submersible pump according to the 

regulations. 
Units that are permanently installed must be 
grounded in compliance with nationally appli-
cable standards. If a separate protective earth 
conductor is available, it must be connected 
to the marked drilled hole or earth terminal (

;

using a suitable screw, nut, toothed washer and 

flat washer. The cross-section of the cable for 

the protective earth conductor connection must 
comply with local regulations.

• A power supply separator (main switch) 

must

 be 

provided by the customer!

• We recommend using a residual-current de-

vice (RCD).

• Switchgears must be purchased as accessories.

5.5.1  Technical information

• 

Activation type: Direct

• 

Fuse on mains side: 16 A

• 

Cable cross-section, pump/frequency converter:

• 

Up to 30 m: 1.5 mm²

• 

From 30...90 m: 2.5 mm²

• Cable cross-section, power supply separator/fre-

quency converter:

• 

Up to 1.1 kW: 1.5 mm²

• 

from 1.2 kW: 2.5 mm²

• 

With cable lengths of 5 m or more, always use 
a cable cross-section of 2.5 mm² in order to 

avoid any interference due to voltage drop.

• 

Temperature resistance of the cable: max. 75 °C

• Only slow-blow fuses or K-type circuit breakers 

may be used as a back-up fuse.

5.5.2  Unit with built-in frequency converter 

(TWU 3-...-HS-I)

The version with built-in frequency converter is 
delivered ex works with a connected power sup-
ply cable. This cable has to be extended, accord-
ing to the available space in the borehole, using 
heat-shrink tubing or a cast resin connection, by 
the customer 

before installation

.

Содержание Sub TWU 3-HS Series

Страница 1: ...6063546 Ed 05 05 2019 WH Pioneering for You Wilo Sub TWU 3 HS High Speed en Installation and operating instructions...

Страница 2: ...Fig 1 Fig 1 Fig 1 Fig 3 Fig 2 TWU 3 HS ECP TWU 3 HS I 1 2 3 4 5 1 2 3 6 4 5 1 2 3 ca 2 l min 0 20 m min 0 30 m 7 8 3 1 1 2 4 5 6 6 1 1 1 1 TWU 3 HS E CP TWU 3 HS I 7...

Страница 3: ...Fig 1 Fig 1 Fig 5 Fig 6 Fig 4 1 4 2 3 ON OFF RESET PUMP ON FAILURE LINE 1 2 3 1 5 5 4 4 2 3 6 7 8...

Страница 4: ...Fig 10 Fig 11 Fig 9 Fig 8 Fig 7 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2 1...

Страница 5: ...1 Delivery 12 4 2 Transport 12 4 3 Storage 12 4 4 Return delivery 13 5 Installation 13 5 1 General 13 5 2 Installation types 13 5 3 Installation 13 5 4 Dry running protection 16 5 5 Electrical connect...

Страница 6: ...ss consent of the manufacturer The illustrations used may differ from the original and are only intended as an exemplary representation of the pumps 1 4 Subject to change The manufacturer reserves the...

Страница 7: ...refer to personal injury appear in black and are always accompanied by a safety symbol Danger prohibition or instruction symbols are used as safety symbols Example Danger symbol General hazard Danger...

Страница 8: ...n again until the error has been corrected When the pump is connected to the electrical control panel particularly when electronic devices such as soft start up control or frequency con verters are us...

Страница 9: ...wimming pools or other basins that can be entered there is a risk of electrocution Note Use is strictly forbidden if there are people in the basin If there are no people in the basin protec tive measu...

Страница 10: ...fluid To do this the external frequency converter must be installed in the ascending pipe The internal frequency converter is cooled by the surrounding fluid The frequency converter offers the monitor...

Страница 11: ...0 1 min Max immersion depth 150 m Submerged OTS S1 Non immersed OTE Max switching frequency 30 h Max sand content 50 g m Min flow at motor 0 08 m s Pressure connection TWU TWU 3 HS I TWU 3 02 3 03 HS...

Страница 12: ...ast 1 year The pump should be cleaned thoroughly before it is put into temporary storage Consider the following for storage Place the pump on a firm bearing surface and se cure it against slipping and...

Страница 13: ...tal injury Take all necessary safety precautions to prevent this When installing the pump note the following This work must be performed by qualified per sonnel and electrical work must be performed b...

Страница 14: ...material which would mean that the motor cooling is no longer guaranteed This would result in increased wear of the hydraulics To prevent this it may be neces sary to use a cooling jacket or install...

Страница 15: ...ty for the complete system pump piping cable water column The guy must be fastened to the suspension points eyelets provided on the pressure port for that purpose If these suspension points are not av...

Страница 16: ...tion point a second switch ing point additional electrode is used to obtain a sufficient difference between the activation and deactivation points This prevents constant switching This function can be...

Страница 17: ...o extend the power supply cable this ensures that the cable inlet on the frequency converter seals properly 1 Measure with an insulation tester measuring voltage is 500 V to measure the resistance of...

Страница 18: ...rotection should be set to the rated current shown on the rating plate At partial load we recommend that the motor pro tection be set 5 above the current measured at the duty point 6 Commissioning The...

Страница 19: ...on after a specified time Leak monitoring Rotation direction monitoring and switching of rotation direction Additional connection for functional extension Fig 6 Operating elements Display 1 Green LED...

Страница 20: ...pressure for defining the start up pressure When you open a tap the pressure in the system drops The Dp Start differential pressure can be set in order to prevent the pump from starting each time a t...

Страница 21: ...ump is switched on it must be switched off without delay The start pauses specified in the Technical data section must be observed before starting up again If the fault recurs the unit must be switche...

Страница 22: ...or safety reasons Only auxiliary lifting devices that are in a techni cally perfect condition and lifting gear that has been officially approved may be used for lowering and raising the pump RISK of d...

Страница 23: ...he European Union this symbol can appear on the product the packaging or the accompa nying documentation It means that the electri cal and electronic products in question must not be disposed of along...

Страница 24: ...rror in the internal serial com munication of the frequency converter Contact Wilo customer service 9 E9 Overpressure The set limit value P limit was exceeded If the error repeats check the P limit pa...

Страница 25: ...pump curve or install a unit with greater output 9 2 5 Fault The unit does not run smoothly and is noisy 1 Unit is operating in an inadmissible range Check the operational data of the unit and correct...

Страница 26: ...0 2 Overview of factory and recommended settings for the TWU 3 HS ECP operating parameters Parameter user Setting range Setting Factory setting Recommended Pmax 1 5 7 5 bar 3 0 bar As required Languag...

Страница 27: ...Pioneering for You avrora arm ru 7 495 956 62 18...

Отзывы: