Wilo SiFlux Series Скачать руководство пользователя страница 8

English

Installation and operating instructions Wilo-SiFlux

17

Immediately on conclusion of the work, all safety and protective 
devices must be put back in position and/or recommissioned.

2.7

Unauthorised modification and 
manufacture of spare parts 

Unauthorised modification and manufacture of spare parts will impair 
the safety of the product/personnel and will make void the manufac-
turer's declarations regarding safety.

Modifications to the product are only permissible after consultation 
with the manufacturer. Original spare parts and accessories author-
ised by the manufacturer ensure safety. The use of other parts will 
absolve us of liability for consequential events.

2.8

Improper use

The operating safety of the supplied product is only guaranteed for 
conventional use in accordance with Section 4 of the operating 
instructions. The limit values must on no account fall under or exceed 
those specified in the catalogue/data sheet.

3

Transport and interim storage

The SiFlux is delivered on a pallet and is protected from moisture and 
dust with a transparent plastic cover.

The equipment must be transported by means of authorised load 
devices.

On arrival, inspect the pump immediately for any transport damage. If 
damage is found, the necessary procedure involving the forwarding 
agent must be taken within the specified period.

Before installation, the product must be kept dry, frost-free and pro-
tected from mechanical damage.

3.1

Attachment

WARNING! Danger of personal injury!
Improper transport can lead to personal injury. 

• The stability of the load must be ensured.
• The handling should be done by skilled staff and with authorised 

equipment.

• Transport straps must be secured to the existing transport lugs or 

placed around the base frame.

• The pipes will not withstand loads and should not be used to secure 

loads in transit.

Labels on manifolds refer to these warnings (Fig. 5).

CAUTION! Risk of damage due to incorrect handling!
Loading the pipes in transit can result in leaks. 

4

Intended  use

Purpose

The SiFlux is designed to ensure the flow in function of the pressure 
difference on a HVAC installation (hot and cold water).

Fields of application

They may be used for:

• Hot-water  heating systems
• Cooling and cold water circulation systems
• Industrial circulation systems
• Heat carrier circuits

Restrictions

Typical installation locations are technical rooms within the building 
with other domestic installations. Installing the device directly in 
other used rooms (residential and work rooms) is not intended.

Outdoor installation is not permitted for this series.

Fig. 5: Warning labels on manifold

 

Содержание SiFlux Series

Страница 1: ...iFlux Pioneering for You 4 188 939 Ed 01 2014 05 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedieningsvoorschriften ...

Страница 2: ...Fig 1 SiFlux ...

Страница 3: ...Fig 2 9 2 1 3 5 6 12 7 6 4 ...

Страница 4: ...Fig 3 5 6 12 7 Fig 4 8 10 11 ...

Страница 5: ...re parts 17 2 8 Improper use 17 3 Transport and interim storage 17 3 1 Attachment 17 4 Intended use 17 5 Product information 18 5 1 Type key 18 5 2 Technical data 18 5 3 Scope of delivery 18 6 Description and function 18 6 1 General description 18 6 2 Description of the product 18 6 3 Function of the SiFlux system 20 7 Installation and electrical connection 21 7 1 Installation 21 7 2 Hydraulic con...

Страница 6: ...tions on the safety of the product personnel are not observed this declaration loses its validity 2 Safety These operating instructions contain basic information which must be adhered to during installation operation and maintenance For this reason these operating instructions must without fail be read by the service technician and the responsible specialist operator before installation and commis...

Страница 7: ...internal working operating and safety regulations of the operator are to be complied with 2 5 Safety instructions for the operator This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible...

Страница 8: ...r any transport damage If damage is found the necessary procedure involving the forwarding agent must be taken within the specified period Before installation the product must be kept dry frost free and pro tected from mechanical damage 3 1 Attachment WARNING Danger of personal injury Improper transport can lead to personal injury The stability of the load must be ensured The handling should be do...

Страница 9: ...pplied completely piped and ready for connection The only connections that have to be made are for suction and discharge and also the power mains 6 2 Description of the product Mechanic and hydraulic installation components Fig 2 3 and 4 The compact installation is mounted on a steel base frame with vibra tion absorbers pos 3 It consists of a group of 3 or 4 in line pumps with electronics pos 1 wh...

Страница 10: ...kets pos 9 All electronic components are prewired upon delivery These Installation and operating instructions describe the complete installation of the SiFlux In line pumps pos 1 Different types of pumps are installed in the SiFlux depending on the intended use and the performance parameters required The number of these pumps can vary between 3 and 4 The enclosed Installation and operating instruc...

Страница 11: ...1 DN 125 21 IL E 40 170 5 5 2 SC 16 T4 2 1 DN 125 31 IP E 40 120 1 5 2 SC 16 T4 3 1 DN 150 31 IP E 40 160 4 2 SC 16 T4S 3 1 DN 150 31 IL E 40 170 5 5 2 SC 16 T4 3 1 DN 150 21 IP E 50 130 2 2 2 SC 16 T4 2 1 DN 150 21 IP E 50 150 4 2 SC 16 T4 2 1 DN 150 21 IL E 50 180 7 5 2 SC 16 T4 2 1 DN 150 31 IP E 50 130 2 2 2 SC 16 T4 3 1 DN 200 31 IP E 50 150 4 2 SC 16 T4 3 1 DN 200 31 IL E 50 180 7 5 2 SC 16 ...

Страница 12: ...pes are recommended for this purpose in order to avoid stresses on the pipe connections and minimise the transmission of installation vibrations to the building installation If the pumped fluid and pipe material cause dirt it is obligatory to install a strainer in front of the pump You can also install a SiClean or SiClean Comfort to clean the water and WEH WEV to maintain the pressure level 7 3 E...

Страница 13: ...e enclosed Installation and operating instructions 8 2 Commissioning the installation After all preparations and checks according to section 8 1 General preparation and checking on page 22 have been done switch on the main switch and set the control system to the automatic mode CAUTION Damage to the pump Danger of damage due to incorrect handling Do not let the pump operate with a closed pressure ...

Страница 14: ...h off the electric supply of the switchgear and then check if the shaft turns smoothly If it is blocked dismantle the pump Winding fault Disconnect the terminal board of the terminal block and check the stator insulation to earth Replace the motor if necessary 10 3 NO DELIVERY PRESSURE Flow higher than system capabili ties Plantoreplacethesystembyamore adequate one do not forget to con tact us in ...

Страница 15: ...ame description of the spare part All data on the pump and motor rating plate 12 Disposal Proper disposal and recycling of this product prevents damage to the environment and risks to personal health Proper disposal requires the drainage and cleaning and the disman tling of the pump unit Lubricants must be collected The pump components are to be sepa rated according to material metal plastic elect...

Страница 16: ...English Installation and operating instructions Wilo SiFlux 25 ...

Страница 17: ...rective Basse Tension 2006 95 CE _ Elektromagnetische Verträglichkeit Richtlinie 2004 108 EG _ Electromagnetic compatibility 2004 108 EC _ Compabilité électromagnétique 2004 108 CE EG KONFORMITÄTSERKLÄRUNG EC DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE CE Als Hersteller erklären wir hiermit dass die Pumpenbauarten der Baureihe We the manufacturer declare that the pump types of the series W...

Страница 18: ...ства Koneet 2006 42 EY Sähkömagneettinen Yhteensopivuus 2004 108 EY EZ smjernica o strojevima 2006 42 EZ Elektromagnetna kompatibilnost smjernica 2004 108 EZ Maskiner 2006 42 EF Elektromagnetisk Kompatibilitet 2004 108 EF Μηχανήματα 2006 42 ΕΚ Ηλεκτρομαγνητικής συμβατότητας 2004 108 ΕΚ Машини 2006 42 ЕО Електромагнитна съвместимост 2004 108 ЕО WILO SE prohlašuje že výrobky uvedené v tomto prohláše...

Страница 19: ... 2004 108 WE WILO SE erklærer at produktene nevnt i denne erklæringen er i samsvar med følgende europeiske direktiver og nasjonale lover WILO SE oświadcza że produkty wymienione w niniejszej deklaracji są zgodne z postanowieniami następujących dyrektyw europejskich i transponującymi je przepisami prawa krajowego WILO SE declara que os materiais designados na presente declaração obedecem às disposi...

Страница 20: ......

Страница 21: ...20 27442100 D Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 Ireland WILO Ireland T 353 61 227566 Italy w v Borromeo Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7 727 2785961 Korea v D w F T 82 51 950 8000 Latvia 1019 Riga T 371 6714 5229 Lebanon WILO LEBANON SARL Lebanon T 961 1 888910 Lithuania 03202 Vilnius T 370 5 2136495 Morocco WILO MAROC SARL 2060...

Страница 22: ...Pioneering for You WILO SE Nortkirchenstraße 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com ...

Отзывы: