Wilo SCPV Скачать руководство пользователя страница 10

Installation and operating instructions  Wilo 

 SCPV pumps 

 

should  be  secured  against  slipping  along  with 
protective  cover  to  prevent  damage  to  the 
product,  paint  and/or  injury to personnel. 
When lifting the  pump  in combination  with the 
pump  stool  and  motor  stool,   the  lifting  tackle 
should    be    attached    to    the    lifting    lugs 
provided  on  the   base  plate  side  member.  To 
lift  the  pump  the    lifting  slings  should  pass 
beneath  the    pump  body  at    suction    and 
delivery flanges  (see  lifting diagrams  - see  also 
general  safety   Information,  chapter   2).  These 
must   have  sufficient   load  bearing  capacity  to 
ensure   that  the   product   can  be  transported 
safely.(Refer Figure 1) 

 

3.2    Delivery

 

On    arrival,  the    delivered    items    must    be 
inspected  for  damage  and  a  check  made  that 
all parts  are  present.  If any parts  are  damaged 
or  missing,  the  transport  company  or  the 
manufacturer   must  be  informed  on the  day of 
delivery.   Any claim made  at  a  later  date  will be 
deemed    invalid.  Damage   to   parts    must   be 
noted      on    the    delivery    or    freight 
documentation. 

 

3.3    Storage

 

 

3.3.1 Short-term storage  (less  than 3 month)

 

The  equipments    as  shipped  have  adequate 
protection  for  short-term  storage   in a  covered, 
dry  and  ventilated   location  at  the  job  site  prior 
to installation. 
If the  pump  is not  installed  immediately after 
delivery, it  must   be  stored   in  a  dry and  clean 
place  with  sufficient   ventilation,   no  vibration, 
no   freezing   and   the   temperature   variations 
must  be  smooth.   Bearings and couplings  must 
be  protected  against   sand,  dust   and  foreign 
bodies.  To avoid  corrosion  and jamming, please 
lubricate    the    pump    and    make    turn    the 
rotating   elements   for  several  turns  at   least 
once   a  week.  Pre-packed   desiccants  may  be 
used   to   absorb   moisture   &  keep   the  pump 
dry.  It  must  be  removed  before    putting    the 
pump on operation. 

3.3.2 Long-term storage  (more than 3 month)

 

If the  equipment  will be  subject  to  extended 
storage   condition   prior  to   installation,   then 
the  manufacturer  must  be informed about 

storage   duration,  so  that  special  protection 
can be recommended. 

  

Place   the   SCPV pumps   horizontally   on   firm 

foundation and secure  it against  falling. 

  

The machine  must  be  protected from  direct 

sunlight, heat,  dust,  and frost. 

 

The  rotors  or  propellers  must  be  turned  at 
regular  intervals.  This  prevents    the    bearing 
from  locking  and  the  film of lubricant  on  the 
mechanical  shaft  seal is renewed. 

  

For  mechanical  seal,  we  recommend:  relative 

air    humidity    below    65%,    temperature 
between  15°C  and  25°C.  Direct  exposure   of 
the  mechanical  seal  to  heat  (sun, heating)  as 
well  as  to  ozone,  present  or  produced  by 
ultraviolet  light  (halogen  or  fluorescent 
lamps),  must  be  avoided  because   of  the  risk 
of embrittlement of elastomeric materials. 

 

3.4    Pump returning  back to the  supplier

 

Products,  which  are  delivered  back  to  the   plant, 
must    be  clean  and  correctly  packaged.  In  this 
context,  clean  means  that    impurities  have  been 
removed   and   decontaminated   if   it   has   been 
used    with  materials,    which  are  hazardous    to 
health. 
The    packaging    must    protect     the    product 
against damage. 

CAUTIO N! Guarantee  not applicable!

 

Products,  which  are  not  suitably  packaged  for 
delivery back, are no longer  covered  by guaran- 
tee!

 

 

 

4 I n t e n d e d use

 

The  pump  supplied  is  intended  for  specific  fluid. 
Refer  pump  data  sheet  and  order  confirmation. 
For  any  change  in  pumped  fluid  refer  Wilo 
beforehand.  Vertical  Split  Case  pumps  are  used  in 
water  supply,  water-circulating  systems,  injection 
water,  spray  pond,  air-conditioning,  water 
treatment,  Sprinkler  & drip  irrigation,  fire  fighting, 
juices etc. If the operating conditions are different 
of  the  specifications  given  in  the  order,  (i.e.  type 
of liquid,  temperature  or duty point),  the end user 
must ask  a written agreement  to Wilo on the  new 
operating conditions before starting the pump. 

Содержание SCPV

Страница 1: ...Wilo SC PV_ 201 310 10_ E0 3 Wilo SCPV pumps en Installationand operating instructions...

Страница 2: ...l and maintain the pump shall be responsible for hassle free installation operation or maintenance of the product This document is prepared with at most care to ensure correct and accurate information...

Страница 3: ...tion and operating instructions Wilo SCPV pumps 2 Fig 1 Pump Handling 3 1 Fig 2 Pump Foundation 7 2 1 Bare Pump HorizontalLifting bar Lifting ropes Motor Motor Stool Split case Pump Pump Stool Foundat...

Страница 4: ...Installation and operating instructions Wilo SCPV pumps 3 Fig 3 Coupling assembly 7 2 3 Fig 4 Suction Layout 7 2 5 Fig 5 Suction Layout 7 2 5...

Страница 5: ...Installation and operating instructions Wilo SCPV pumps 4 Fig 6 Discharge Layout 7 2 6 Fig 7 Discharge Layout 7 2 6...

Страница 6: ...Installation and operating instructions Wilo SCPV pumps 5 Fig 8 Gland Packing Details 7 2 7 Fig 9 Bolt tighting sequence 9 5 2...

Страница 7: ...ended use 9 5 Product information 10 5 1 Data plate 10 5 2 Type key 10 5 3 General description 10 5 4 Scope of delivery 11 5 5 Accessories 11 6 Description and function 11 6 1 Description of the produ...

Страница 8: ...uries WARNING The user can suffer serious injuries Warning implies that serious injury to persons is probable if this information is disregarded CAUTION There is a risk of damaging the pump installati...

Страница 9: ...e when the pump is supplied along with motor panels When motor panel is in end user s scope of supply it isadvised to go for CE approved motors panels Environmental safety Disposal of any unwanted scr...

Страница 10: ...p on operation 3 3 2 Long term storage more than 3 month If the equipment will be subject to extended storage condition prior to installation then the manufacturer must be informed about storage durat...

Страница 11: ...odel dependent Discharge nominal diameters DN 50 up to 400 Flange standard PN 16 25 ISO 7005 2 as needed Limit of fluid temperature min max Mechanical seal version C Gland packing version C 8 up to 12...

Страница 12: ...ion for neck rings Tapings are provided in top half casing for taking water seal flushing connection to the stuffing box Tapings are also provided on top of casing for mounting air cock for venting Th...

Страница 13: ...sher 2105 Non drive end shaft sleeve 2410 Gland packing 3001 Cowl Nut L H 2300 Lantern ring 3031 Sleeve nut L H 2070 Water Thrower 3032 Sleeve nut R H 3250 Coupling key For Mechanical Seal No Part des...

Страница 14: ...d be taken to bar persons from standing beneath a suspended load Further more it is also prohibited to move suspended loads over exposed workplaces where people are present The fastening devices shoul...

Страница 15: ...motor Avoid exposure of the pump to direct sunlight An appropriate solution to avoid frost must be implemented CAUTION Risk of material damage Ensure sufficient ventilation heating if the ambient tem...

Страница 16: ...t mix in the proportion specified earlier for foundation bolt grouting should be used 7 2 3 Alignment of the pumps and its driving units When the sole plate is leveled and the satisfactory alignment i...

Страница 17: ...xed relation to the diameter of the suction branch of the pump The size of the pipe must be such that friction losses are kept to a minimum For example a long suction pipe or one with numerous bends w...

Страница 18: ...Mechanical seal CAUTION Damage to the pump Never start the pump without liquid inside otherwise the mechanical seal will be damaged instantaneously No real operation is required during the setup of t...

Страница 19: ...ay become very hot depending on the operating state of the pump or system fluid temperature CAUTION Danger sealing system damage Any attempt to run the pump dry or partially full may result in seizure...

Страница 20: ...k that all electrical checks on motor relay setting in panel etc have been carried out in accordance with the instructions of motor manufacturer Ensure that mechanical seal connection is provided as s...

Страница 21: ...g the pump If the gland plate is too tight the packing stuff willbe immediately damage At the beginning of the operation the leak at the gland packing should be important It should reduce progressivel...

Страница 22: ...in a fortnight and values compared with that of previous records Check that there is sufficient leakage from the gland packing to ensure proper cooling and lubrication If applicable For mechanical se...

Страница 23: ...wearable components may require renewal Measurements should be taken and recorded of all wearable components at the first and every subsequent overhaul period Reference to these records will enable a...

Страница 24: ...r neck will indicate the amount of diametrical clearance between the casing neck ring and the impeller neck 9 4 2 Shaft Sleeves The shaft sleeve should be examined to see if it is grooved or generally...

Страница 25: ...must be smaller than the corner radius of the track located against the abutment The edge of the abutment must be reduced or chamfered a burred edge can tilt or distort a bearing track If after inspe...

Страница 26: ...on split flange of bottom half casing Position the top half casing by crane chain pulley block with respect bottom half casing so that split faces match Use withdrawal gear trolley crane to support t...

Страница 27: ...pump wear rings and their nuts For the pumps equipped with Gland packing include the gland plate and lubrication spacer For5 years of normal operation Take the same lot of part as for 3 years and add...

Страница 28: ...Gland 1 15 Stud for gland 2 16 Bearing end cover Drive End 1 17 Bearing DriveEnd 1 18 Bearing housing DriveEnd 1 19 Thrust collar 1 20 Bearing end cover NonDrive End 1 21 Stud for bearing end cover 1...

Страница 29: ...Plate 2 14 Stud for gland 2 15 Bearing end cover Drive End 1 16 Bearing Drive End 1 17 Bearing housing Drive End 1 18 Thrust collar 1 19 Bearing end cover Non Drive End 1 20 Stud for bearing end cover...

Страница 30: ...r leaks into suction line Tighten pipe joints with solution 8 Air leaks into pump through stuffing boxes Ensure stuffing box sealing 9 Foot valve too small or leaking Replace I Attend 10 Foot valve pa...

Страница 31: ...of Provide clean liquid for flushing shaft or shaft sleeve 41 Excessive thrust caused by mechanical failure Check pump operation and assembly inside pump or by failure of hydraulic balancing device i...

Страница 32: ...eve N D E 2300 Lantern ring 2310 Gland 2410 Gland packing 2600 Ball bearing 2702 Baering bush 2752 Bearing end cover D E inner 2753 Bearing end cover D E outer 2761 Bearing housing D E 2831 Bearing bu...

Страница 33: ...sleeve N D E 2111 Spacer sleeve 2420 Mechanical seal 2421 Gland Plate 2402 Stuffing box bush 2601 Bearing 2700 Baering bush 2752 Bearing end cover D E inner 2753 Bearing end cover D E outer 2761 Bear...

Страница 34: ...ot B N A 18 SCPV 150 530 HA 6311 ZZ Finocot B N A 19 SCPV 200 310 HA 3380 A Finocot B Grease 20 SCPV 200 320 HA 3380 A Finocot B Grease 21 SCPV 200 370 HA 3380 A Finocot B Grease 22 SCPV 200 360 HB 33...

Страница 35: ...95 13 SCPV 150 290 HA 16 3 230 81 14 SCPV 150 390 HA 17 5 3 275 95 15 SCPV 150 350 HA 17 5 3 275 95 16 SCPV 150 440 HA 17 5 3 275 95 17 SCPV 150 580 HA 20 3 330 114 18 SCPV 150 530 HA 20 3 330 114 19...

Страница 36: ...and Remove gland packing as well as logging ring In case of Mechanical seal remove the nuts of seal gland plate Remove all split flange nuts and the two dowel pins Withdraw the casing top by sliding o...

Страница 37: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ __ Mather and Platt pumps Ltd Part of Wilo SE Germany Mumbai Pune Road Chinchwad Pune 411 019 Maharashtra India Tel 91...

Отзывы: