5
Wilo-ICL - Installation and Operation Manual
1.
1.1
i.
ii.
iii.
General
About these instructions:
These instructions must be read in full prior
to installation. Failure to comply with these
instructions may lead to serious injury or
damage to the pump.
Once the pump is installed, give these
instructions to the operator.
These instructions should be kept in the
vicinity of the pump. They serve as a reference
in case of later problems.
Wilo is not liable for damage arising from non-
compliance with these instructions.
2.
2.1
2.1.1
2.1.2
2.1.3
2.1.4
2.1.5
Safety
These operating instructions contain basic
information concerning the installation and
commissioning of the system and should be
read by the service technician and responsible
operator prior to proceeding. Observe the
special safety instructions and understand the
danger symbols throughout this document.
Warning Notices:
Important safety notices are categorized as
follows:
Safety Sticker:
Safety stickers giving important instructions
on how to handle the pump are located on the
motor. The instructions on the safety sticker
must be strictly obeyed.
Qualifications:
The pump may only be installed by qualified
personnel. The electrical systems may only
be connected by qualified electricians.
Additionally, national regulations concerning
the qualifications of personnel must be obeyed
Modification, Spare Parts:
No technical alterations or modifications may
be made to the pump. Use only original spare
parts.
Electrical Power Supply
Working with electrical current could cause
serious risk of bodily injury, therefore:
3.
2.1.6
2.1.7
3.1
i.
ii.
iii.
i.
ii.
i.
ii.
iii.
iv.
v.
Before starting work on the pump, switch off
the power and secure it against reconnection.
Do not bend or clamp power cable or expose it
to heat sources.
Do not immerse the pump in water or other
liquids or expose it to spray water or moisture.
Rotating Components
The pump contains rotating components
that are exposed if the pump housing is open.
Touching the rotating components can cause
serious injury, therefore:
Before opening the pump housing, switch off
the motor and secure against reconnection.
Never switch on the motor when the pump
housing is open.
High Deadweight
The pump has a very high deadweight,
depending on the model. If the pump is
dropped or it falls, there is a risk of death,
therefore:
Exercise caution when lifting or transporting.
Never walk under suspended loads.
Always put the pump and pump parts down
ensuring they cannot tip over.
Only use the transportation methods
described in these operating instructions L
Page 6-7.
Before loosening screws, secure the pump
parts to prevent them from falling.
Technical Data
Type Key
Type Key
Example: ICL 4X4X8.86-TEFC-4-3-
184TCZ-460-CI
Wilo Cronoline ICL
Series: Inline Pump ICL
4
Nominal Diameter of Suction End (inches
4
Nominal Diameter of Discharge End
(inches)
8.86
Impeller Diameter (inches)
TEFC
Totally Enclosed Fan Cooled
4
Number of Poles
3
Horse Power
184 TCZ
Motor Frame
460
Voltage
CI
Cast Irion
DI
Ductile Iron