background image

English

16

WILO SE 11/2019

the risks involved have been assessed. Children 
must not be allowed to play with the device. 
Cleaning and maintenance work performed by the 
user must not be carried out by unsupervised chil-
dren

.

• If hot or cold components of the product/system 

pose a danger, it is the customer’s responsibility to 
guard them against being touched.

• Guards which protect personnel from coming into 

contact with moving components (e.g. couplings) 
must not be removed while the product is in oper-
ation.

• Hazardous fluids (i.e. which are explosive, toxic or 

hot) which have leaked (e.g. from the shaft seals) 
must be disposed of so that they pose no danger 
to persons or to the environment. National statu-
tory provisions must be respected.

• Danger from electrical current must be eliminated. 

Local directives or general directives [e.g. IEC, VDE 
etc.] and instructions from local energy supply 
companies must be respected.

2.6 Safety instructions for installation and 

maintenance work

The operator must ensure that all maintenance 
and installation work is carried out by authorised 
and qualified personnel, who are sufficiently 
informed having studied the Installation and oper-
ating instructions in detail. Work on the product/
unit must only be carried out when it is at a stand-
still. Compliance with the procedures described in 
the Installation and operating instructions for 
shutting down the product/system is mandatory.
Immediately on conclusion of the work, all safety 
and protective devices must be put back in posi-
tion and recommissioned.

2.7 Unauthorised modification and manufacture 

of spare parts

Unauthorised modification of components and 
use of unauthorised spare parts will impair the 
safety of the product/personnel, and will render 
the manufacturer’s declarations regarding safety 
void. Modifications to the product are only per-
missible following consultation with the manu-
facturer.
Original spare parts and accessories authorised by 
the manufacturer ensure safety. The use of other 
parts absolves the manufacturing company of any 
and all liability.

2.8 Improper use

The operational reliability of the supplied product 
is only guaranteed for conventional use in accord-
ance with Chapter 4 of the Installation and oper-
ating instructions.
The limit values must on no account fall below or 
exceed the values specified in the catalogue/data 
sheet.

3 Transport and temporary storage

When you receive the device, check that it has not 
been damaged during transport. If you notice a 
fault, take all necessary action with the carrier 
within the time allowed.
The pressure-boosting system is delivered on a 
pallet. It is protected from moisture and dust by 
transparent plastic shrink-wrap.
The transportation and storage instructions 
located on the packaging must be observed.

• The system must be transported using a lifting 

device suitable for carrying the load.

WARNING!
The static stability of the device must be taken 
into account because, due the pumps’ design, 
the system’s centre of gravity shifts towards its 
upper part.
Maintenance must be performed by qualified 
personnel using suitable and authorised equip-
ment. Lifting straps must be fastened to the 
transport lugs designed for this purpose or 
placed around the steel baseplate. A sticker on 
the plastic shrink-wrap contains the safety 
instructions (Fig. 2).
The collector tanks are not suitable for handling 
the pressure-boosting system and must not be 
used to fix loads.
The stickers attached to the collector tanks pro-
vide a reminder of these instructions (Fig. 3).
CAUTION! Risk of damage to the installation
If the equipment delivered must be installed at a 
subsequent date, store it in a dry place and pro-
tect it from shocks and any other external 
effects (humidity, frost, etc.).
Temperature range for transport and storage:
 -30 °C to +60 °C.

Handle the product with care so as not to damage 
it prior to installation.

4 Intended use

Intended use of the pressure-boosting system is 
to keep a fire hose cabinet pressurised and supply 
it with water in order to protect buildings (hospi-
tals, apartment buildings, schools, industrial 
premises, commercial centres, etc.).
The water supply to the pressure-boosting sys-
tem may be taken from the municipal water sup-
ply or from a replenishment reservoir.

Содержание COF-2 Helix

Страница 1: ...Wilo COF 2 Helix Pioneering for You 4 218 091 Ed 02 2019 11 Wilo fr Notice de montage et de mise en service en Installation and operating instructions...

Страница 2: ...Fig 1...

Страница 3: ...Fig 2 Fig 3...

Страница 4: ......

Страница 5: ...fr Notice de montage et de mise en service 6 en Installation and operating instructions 14...

Страница 6: ...interm diaire 8 4 Application 8 5 Donn es techniques 9 5 1 D signation 9 5 2 Caract ristiques techniques 9 5 3 Fourniture 9 5 4 Variantes 9 5 5 Coffret de commande 9 5 6 Accessoires 9 6 Description e...

Страница 7: ...le produit l installation Attention signale une consigne dont la non observation peut engen drer un dommage pour le mat riel et son fonc tionnement AVIS Remarque utile sur le maniement du produit Ell...

Страница 8: ...ge d origine et d accessoires autoris s par le fabricant garantit la s curit L utilisation d autres pi ces d gage la soci t de toute responsabilit 2 8 Modes d utilisation non autoris s La s curit de f...

Страница 9: ...u moteur par rapport la terre Dispositif obligatoire pour les ERP Sans CPI 5 5 Coffret de commande Le coffret de commande Fig 1 rep 3 assure la protection et le pilotage du surpresseur Se reporter la...

Страница 10: ...ret de commande par un c ble deux conducteurs 7 3 Raccordement hydraulique L alimentation en eau du surpresseur est possible partir du r seau de distribution d eau municipale version V ou partir d une...

Страница 11: ...s l installa tion Isoler et vidanger le r servoir sous pression membrane En cas de besoin vidanger enti rement l installa tion 9 Entretien Seul le personnel qualifi est habilit effectuer les travaux...

Страница 12: ...de l arbre si celui ci est bloqu proc der au d montage de la pompe D faut bobinage D connecter le bornier du moteur concern et contr ler la r sistance aux bornes et l isolation du stator par rapport l...

Страница 13: ...imination interdite par le biais des ordures m nag res Dans l Union europ enne ce symbole peut appa ra tre sur le produit l emballage ou les documents d accompagnement Il signifie que les produits lec...

Страница 14: ...sport and interim storage 16 4 Application 16 5 Technical information 17 5 1 Type key 17 5 2 Technical data 17 5 3 Delivery 17 5 4 Variants 17 5 5 Switchgear 17 5 6 Accessories 17 6 Description and fu...

Страница 15: ...aution signifies that damage to the product and its functioning is likely if this instruction is not observed NOTICE Useful information on handling the product It draws attention to possible problems...

Страница 16: ...g company of any and all liability 2 8 Improper use The operational reliability of the supplied product is only guaranteed for conventional use in accord ance with Chapter 4 of the Installation and op...

Страница 17: ...sulation monitoring device With CPI The switchgear contains CPI for the pump and monitors the motor insulation and earthing Mandatory equipment for energy related products ErP Without CPI 5 5 Switchge...

Страница 18: ...in the replenishment reservoir and must be connected to the switchgear by a cable with two conductors 7 3 Hydraulic connection The water supply to the pressure boosting sys tem may be taken from the m...

Страница 19: ...persons Close the gate valves before and after installation Isolate and drain the pressurised diaphragm pres sure vessel If necessary drain the system entirely 9 Maintenance Maintenance and repair wor...

Страница 20: ...ocked proceed to dismantle the pump Winding malfunction Disconnect the terminal of the motor concerned and check the resistor at the terminals and the stator s insulation to earth Replace the motor if...

Страница 21: ...l in domestic waste is forbidden In the European Union this symbol can appear on the product the packaging or the accompanying documentation It means that the electrical and electronic products in que...

Страница 22: ...ortmund und entsprechender nationaler Gesetzgebung Person authorized to compile the technical file is EN IEC 63000 et aux l gislations nationales les transposant EN ISO 12100 comply also with the foll...

Страница 23: ...ysten sek niihin sovellettavien kansallisten lakiasetusten mukaisia WILO SE ndearbha onn an cur s os ar na t irg at i r iteas seo siad i gcomhr ir leis na for lacha at sna treoracha seo a leanas na h...

Страница 24: ...f ljande europeiska direktiv och nationella lagstiftningar som inf r dem WILO SEbu belgede belirtilen r nlerin a a daki Avrupa y netmeliklerine ve ulusal kanunlara uygun oldu unu beyan etmektedir WIL...

Страница 25: ...DWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FRP O...

Страница 26: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: