Product description
12
WILO SE 2017-12
P 13
P 17
Sealing chamber
o
o
Key: - = not available/possible, o = optional, • = as standard
All the monitoring devices fitted must always be connected!
Monitoring of motor compartment
The motor compartment monitoring protects the motor winding from short-circuits.
The moisture is measured by an electrode.
Monitoring of motor winding
The thermal motor monitoring protects the motor winding from overheating. Bimetallic
strips are installed as standard for the temperature measurement. As an option, the
temperature can also be measured with PTC sensors. The design of the thermal motor
monitoring depends on the motor:
▪ P 13 motor:
The thermal motor monitoring is designed as temperature limiter. When the temperat-
ure is reached, deactivation with reactivation lock must take place.
▪ P 17 motor:
The thermal motor monitoring is designed as temperature controller. This allows the
measurement of two temperatures. When the low temperature is reached, an auto-
matic reactivation can be initiated after cooling the motor. When the high temperature
is reached, the unit must deactivate with reactivation lock.
Sealing chamber monitoring
The sealing chamber can be equipped with an external pencil electrode. The electrode
registers fluid ingress through the mechanical seal on the fluid side. An alarm or deac-
tivation of the pump can therefore take place through pump control.
4.3
Operating modes
Operating mode S1: Continuous duty
The pump can operate continuously at the rated load without exceeding the permiss-
ible temperature.
Operating mode S2: Short-time duty
The maximum operating period is specified in minutes, e.g. S2-15. The pause must last
until the machine temperature no longer differs from the temperature of the coolant by
more than 2 K.
Operating mode S3: Intermittent periodic duty
This operating mode defines a switching cycle in a combination of periods of operation
and standstill. Specified value (e.g. S3 25 %) relates to the operating time. The switch-
ing cycle has a duration of 10 min.
If two values (e.g. S3 25 %/120 s) are specified, the first value relates to the operating
time. The second value specifies the max. period of the switching cycle.
Operating mode: Non-immersed operation
The “non-immersed operation” operating mode describes the possibility of the motor
emerging during the drainage pumping sequence. This allows a further lowering of the
water level as far as the upper edge of the hydraulics. Observe the following points dur-
ing non-immersed operation:
▪ Operating mode
– P 13 motor:
The motor can be run non-immersed in “non-immersed” operating mode.
– P 17 motor:
The motor can be run non-immersed for short periods.
CAUTION! To protect the
motor winding from overheating, the motor must be equipped with a temperature
controller! If only one temperature limiter is installed, the motor must not emerge
during operation.
▪ Max. fluid and ambient temperature: The max. ambient temperature corresponds to the
max. fluid temperature shown on the rating plate.
4.4
Operation with frequency con-
verter
Operation on the frequency converter is permitted. Refer to the appendix for the relev-
ant requirements!
Содержание 6069866
Страница 8: ...Pioneering for You Wilo Rexa CUT GE 6069819 Ed 02 2017 12 en Installation and operating instructions...
Страница 9: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 52: ...Pioneering for You Wilo Rexa PRO 6063548 Ed 06 2017 12 en Installation and operating instructions...
Страница 53: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 100: ...Pioneering for You Wilo Rexa CUT GE 6069819 Ed 02 2017 12 en Installation and operating instructions...
Страница 101: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 144: ...Pioneering for You Wilo Rexa PRO 6063548 Ed 06 2017 12 en Installation and operating instructions...
Страница 145: ......
Страница 188: ......
Страница 189: ......
Страница 190: ......