Wilo 29992313 Скачать руководство пользователя страница 12

12

29992343 COR 

2MHIE 205/SCe_DM

29992344 COR 

2MHIE 403/SCe_DM

29992347 COR 

2MHIE406/SCe_DM

29992345 COR 

2MHIE 803/SCe_DM

29992346 COR 

2MHIE1602/SCe-DM

29992348 COR 

3MHIE 205/SCe_DM

29992350 COR 

3MHIE 403/SCe_DM

29992349 COR 

3MHIE 406/Sce_DM

29992352 COR 

3MHIE 803/SCe_DM

29992351 COR 

3MHIE1602/SCe_DM

Motors

4148406

MHIE205

4148412

MHIE403

4148418

MHIE406

4148412

MHIE803

4148430

MHIE1602

Vessel

2815472

8L Expansion V

essel

Contr

ols

 

2549490

2X16A Contr

ol Panel

2549491

3X16A Contr

ol Panel

2085909

Pr

essur

e Sensor

2818575

Low W

ater Switch

Valv

es

2027870

1 1/4” Non R

eturn V

alv

e

2518444

1 1/4” NR

V Housing

29990059

1 1/4” Ball V

alv

e

2012230

1 1/2” Non R

eturn V

alv

e

2518445

1 1/2” NR

V Housing

2518806

2” Non R

eturn V

alv

e

2518582

2” NR

V Housing

29990000

1 1/2” Ball V

alv

e

2520853

3/4" V

essel V

alv

e

Spar

es 3 C

OR 2-3 MHIE***/SCE-DM

Содержание 29992313

Страница 1: ...I404 SCe_EM 29992336 COR 3MHI404 SCe_EM 29992377 COR 2MHI404 SCe_EM_T260AB 29992321 COR 2MHI405 SCe_EM 29992337 COR 3MHI405 SCe_EM 29992378 COR 2MHI405 SCe_EM_T260AB 29992322 COR 2MHI406 SCe_EM 299923...

Страница 2: ...4 5 3 Hygiene 4 5 4 Electrical Connections 4 5 5 Low Water Cut Out Switch 5 5 6 Operation 5 6 Commissioning Maintenance 6 1 Commissioning 5 6 2 Maintenance 5 7 Warranty 6 8 Tables Table 1 SCe Panel F...

Страница 3: ...Wilo approved spares must be used at all times For information on spares see section 10 Spares of this manual or contact spareparts uk wilo com or Ph 01283 523 000 3 Transport and Storage SCe booster...

Страница 4: ...ulic Connections The SCe booster set is connected to the mains water supply via a storage tank An isolation valves must be installed between the tank discharge manifold and the booster as standard onm...

Страница 5: ...0 factory set at 300 seconds oPipe fill speed 5 8 4 0 factory set at 60 oTurn pumps on 3 1 0 0 WARNING Changes made to the drives may hamper performance or cause damage to the pumps 6 Commissioning M...

Страница 6: ...ulty No electrical connection to the sensor Repair the electrical connection E054 Connection partner lost Fault in the CAN connection between the switchgear and pumps Check cable connection Check acti...

Страница 7: ...r has short circuit Dismantle the frequency converter of the pump check and replace it if required E025 Immediately Immediately Missing phase at the motor Check the connection between motor and conver...

Страница 8: ...Connections Figure 3 EM Electrical Connections For detailed wiring diagrams see the elctrical drawings refer to the drawings in the customer pack For detailed wiring diagrams see the elctrical drawing...

Страница 9: ...9 Figure 4 Low Water Cut Out Switch Setting Figure 5 General Arrangement...

Страница 10: ...375 COR 2MHI402 SCe T260 29992376 COR 2MHI403 SCe T260 29992377 COR 2MHI404 SCe T260 29992378 COR 2MHI405 SCe T260 29992379 COR 2MHI406 SCe T260 Motors 4024283 MHi202 4024285 MHi203 4024287 MHi204 421...

Страница 11: ...Ce EM Motors 4024283 MHi202 4024285 MHi203 4024287 MHi204 4210718 MHi205 4210722 MHi206 4024293 MHi402 4024295 MHi403 4210725 MHi404 4210732 MHi405 4210735 MHi406 4210739 MHi802 4210743 MHi803 4210747...

Страница 12: ...s 4148406 MHIE205 4148412 MHIE403 4148418 MHIE406 4148412 MHIE803 4148430 MHIE1602 Vessel 2815472 8L Expansion Vessel Controls 2549490 2X16A Control Panel 2549491 3X16A Control Panel 2085909 Pressure...

Страница 13: ...w Voltage Directive Electromagnetic Compatibility Directive WEEE Directive ROHS Directive As well as following harmonized standards If the above mentioned series are technically modified without our a...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ......

Отзывы: