background image

Transport and interim storage

en

Installation and operating instructions Wilo-Helix V, FIRST V, 2.0-VE 22-36-52

13

Work on the product/unit must only be carried out when at a standstill. It is mandatory
that the procedure described in the installation and operating instructions for shutting
down the product/unit be complied with.

Immediately on conclusion of the work, all safety and protective devices must be put
back in position and/or recommissioned.

2.7

Unauthorised modification and
manufacture of spare parts

Unauthorised modification and manufacture of spare parts will impair the safety of the
product/ personnel and will make void the manufacturer’s declarations regarding safety.

Modifications to the product are only permissible after consultation with the manufac-
turer. Original spare parts and accessories authorised by the manufacturer ensure
safety. The use of other parts will absolve us of liability for consequential events.

2.8

Improper use

The operating safety of the supplied product is only guaranteed for conventional use in
accordance with Section 4 of the operating instructions. The limit values must on no
account fall under or exceed those values specified in the catalogue/data sheet.

3

Transport and interim storage

When receiving the material, check that there has been no damage during the trans-
port. If shipping damage has occurred, take all necessary steps with the carrier within
the allowed time.

CAUTION

Outside influences may cause damages. If the delivered material is to be installed
later on, store it in a dry place and protect it from impacts and any outside influences
(humidity, frost etc.).

The product should be cleaned thoroughly before it is put into temporary storage.
The product can be stored for at least one year.

Handle the pump carefully so as not to damage the unit prior to installation.

4

Application

This pump’s basic function is to pump hot or cold water, water with glycol or other low
viscosity fluids that contain no mineral oil, solid or abrasive substances, or materials
having long fibres. The manufacturer’s approval is required for use to pump corrosive
chemicals.

WARNING
Risk of explosion

Do not use this pump to handle flammable or explosive liquids.

4.1

Applications areas

ƒ

water distribution and pressure boosting

ƒ

industrial circulation systems

ƒ

process fluids

ƒ

cooling-water circuits

ƒ

firefighting and washing stations

ƒ

irrigation systems, etc.

Содержание 2.0-VE 22-36-52

Страница 1: ...Pioneering for You Wilo Helix V FIRST V 2 0 VE 22 36 52 4120943 Ed 12 02 2022 en Installation and operating instructions...

Страница 2: ......

Страница 3: ...8 9 5 6 12 1 2 3 4 10 7 1 2 3 4 10 8 9 5 6 12 7 Fig 1 FIRST...

Страница 4: ...Fig 2...

Страница 5: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1...

Страница 6: ...C D E F G H J K Helix FIRST V F 22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V F 36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V F 52 PN...

Страница 7: ...Fig 8 Fig 9 Fig 10 x2 x4...

Страница 8: ......

Страница 9: ...9 English 10...

Страница 10: ...mproper use 13 3 Transport and interim storage 13 4 Application 13 4 1 Applications areas 13 5 Technical data 14 5 1 Type key 14 5 2 Data table 14 5 3 Scope of delivery 15 5 4 Accessories 15 6 Descrip...

Страница 11: ...e time of going to print 2 Safety These operating instructions contain basic information which must be adhered to dur ing installation operation and maintenance For this reason these operating instruc...

Страница 12: ...procedures 2 4 Safety consciousness on the job The safety instructions included in these installation and operating instructions the ex isting national regulations for accident prevention together wit...

Страница 13: ...ions The limit values must on no account fall under or exceed those values specified in the catalogue data sheet 3 Transport and interim storage When receiving the material check that there has been n...

Страница 14: ...ons without K are equipped with simple mechanical seal S Lantern orientation align with suction pipe X X Care version 1 1 Single phase motor None or 3 Triphase motor With motor 400 460 Motor electrica...

Страница 15: ...HELIX range Designation Article n 2x round counterflanges in stainless steel 1 4404 PN16 DN50 4038587 2x round counterflanges in stainless steel 1 4404 PN25 DN50 4038589 2x round counterflanges in st...

Страница 16: ...ntact with water are made of stainless steel or grey cast iron For aggressive fluid special versions exist with stainless steel only for all wetted components Helix pumps are equipped with a simple me...

Страница 17: ...to ease its disassembly WARNING Risk of accident by hot surfaces The pump must be positioned so that someone cannot come into contact with the hot pump surfaces while operation Install the pump in a d...

Страница 18: ...ited The circulation sense of the fluid is indicated on the identification label of the pump Pump must be installed in such a way that it is not stressed by the pipework The pipes must be attached so...

Страница 19: ...motors must be connected to an approved safety switch The set nominal current must correspond to the electrical data on the motor name plate The supply cable must be laid so that it never touches the...

Страница 20: ...alve on the suction side 2 Remove the filling plug 6b Open the drain priming plug not completely 5b Fill the pump and the suction pipe with water Make sure that there is no air in the pump and in the...

Страница 21: ...temperatures and system pressure close isolating valves before and after the pump First allow pump to cool down These pumps are maintenance free Nevertheless a regular check is recommended every 15 0...

Страница 22: ...ly Pump delivers unevenly Air in pump Evacuate the air in the pump check that the suction pipe is airtight If required start the pump 20 30s open the air bleed screw in order to move air away close th...