![WILMS 1850030 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/wilms/1850030/1850030_operating-manual_982757008.webp)
Infrared heaters with an open combustion chamber (without exhaust pipes)
may only be operated to dry out rooms if at least an air volume sufficient for
combustion is supplied.
The permanent stay of people is prohibited in these rooms.
This ban is indicated by signs at the entrances
point out.
A natural air supply for the combustion is given if e.g. the volume in m³ corresponds
at least to 10 times the nominal heat load in kW of all devices in
operation and natural ventilation is ensured by windows and doors.
Radiant heaters are suitable for selective heating of workplaces and for drying
surfaces that are illuminated by them.
Such uses are both outdoors and in large rooms, e.g. in halls, allowed.
The heater may be operated only by persons who have been advised
in the use of the heater. Please, refer to the operating manual.
Instructed persons are those who have been informed of the tasks assigned
to them and of the possible dangers of improper behaviour and, if necessary,
have been trained.
Repairs and maintenance on electrical components may be carried out by
an electric expert only.
On construction sites the heater may be connected only according to the
VDE standard 0100/5.73§55 with a terminal with FI-protection switch.
Infrared heaters must be checked for their safe working condition according
to the operating conditions as required, but at least once a year by an expert,
and the results of the tests must be recorded in writing and kept until the
next test.