Technical Specifications
Type:
RH 35
Heat capacity:
30 kW
25810 k/cal.
102.400 BTU/h
Fuel:
Heating oil EL / diesel or kersosene
Tank capacity:
53 l
Voltage:
230 V / 50 Hz
Power consumption:
60 W
Rated current:
0,4 A
Control:
Flame control with automatic aftercooling
Fuse:
16 A
Combustion system:
High-Pressure Atomization Burner
Ignition system:
High-Voltage Transformer
Fuel pump pressure:
7 bar
Nozzle:
0,85 G 60° S
Consumption:
2,5 kg/h
Weight:
32 kg
Dimensions: L x W x H in mm
L x B x H in mm
730 x 710 x 965
Noise level:
69 dB (A)