![WILMS 1850030 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/wilms/1850030/1850030_operating-manual_982757023.webp)
Malfunction
Cause
Remedy
Fan does not run.
Interruption in the supply line.
Check/repair power cord, plug etc.
Defective fuse.
Replace fuse.
Defective contacts.
Check/repair resp. Replace electr.
connections and contacts.
Fan runs but heater does
Empty tank.
Fill tank with heating fuel / Diesel
not ignite.
or parafin / cerosene.
Radiation plate is
insufficiently hot.
Clogged nozzle.
Replace nozzle.
Clogged filter
Replace filter element.
Wrong fuel.
Change fuel. Use only heating fuel /
Diesel or parafin / cerosene.
Heater smokes.
Fan delivers insufficient
Increase air supply.
combustion air.
Wrong fuel.
Control fuel.
In case of malfunctions that are not covered here, please contact your supplier