background image

MAINTENANCE

1. Inspect hoses and connections daily. Replace damaged 

components  immediately  with  Williams  Replacement 

Parts only.

2. Tighten connections as needed. Use pipe thread sealing 

compound when servicing connections.

3. Always use clean, approved hydraulic fluid and change 

as  recommended  or  sooner  if  the  fluid  becomes 

contaminated (never exceed 400 hours). Follow pump 

manufacturers  instructions  for  changing  and  adding 

hydraulic fluid. Use only good quality hydraulic fluid. We 

recommend 8H1G or equivalent. 

Never

 use brake fluid, 

transmission fluid, turbine oil, motor oil, alcohol, glycerin 

etc. Use of other than good quality hydraulic oil will void 

warranty and damage the cylinder, pump, hose etc.

4. Use an approved, high-grade pipe thread sealant to seal 

all hydraulic connections. Teflon tape can be used if only 

one layer of tape is used and it is applied carefully (two 

threads back) to prevent the tape from being introduced 

into hydraulic system. A piece of tape could travel through 

the system and obstruct the flow of fluid and adversely 

affect function.

Lubrication & Cleaning

Keep cylinder clean at all times.

1. Any exposed threads (male or female) must be cleaned 

and lubricated regularly, and protected from damage. 

Lubricate with light machine oil.

2. If a cylinder or ram has been exposed to rain, snow, 

sand, airborne abrasive, or any corrosive  environment, it 

must be cleaned, lubricated, and protected  immediately 

after exposure. Daily clean exposed ram with clean cloth 

dampened with light machine oil. Protect exposed ram 

from the elements at all times.

3. Keep the hydraulic system as free of dirt as possible. 

When  not  in  use,  couplers  must  be  sealed  with  dust 

covers. All hose connections must be free of dirt and 

grime. Any equipment attached to the cylinder must be 

kept clean.

Figure 2 - Illustration to bleed air from system

Storage

Cylinders should be stored with ram plunger fully retracted 

in a dry, protected area, not exposed to corrosive vapor, dust 

or other harmful elements. When a cylinder has not been 

used for a period of 4 months, it should be connected to a 

pump and fully extended and then retracted a minimum of 

5 times. This cycle will lubricate the cylinder wall, reducing 

the possibility of corrosion and damage thereof.

How to remove faulty coupler:

If  cylinder  does  not  retract,  secure  load  by  other  means.

Depressurize pump and hose, then remove the cylinder from 

application. Disconnect and replace with new coupler.

Important:

 Do not attempt to grasp with pliers or wrench 

without first wrapping the jaws of such tool with rags or 

similar padding.

How to bleed air from system:

1.  Place  pump  at  a  higher  elevation  than  the  hose  and 

cylinder as shown in figure 2 below.

2. Operate pump to fully extend and retract the cylinder 2 

or 3 times. The objective is to force the air bubbles up 

hill and back to the pump reservoir.

3. Follow pump instruction manual to bleed the air from 

pump  reservoir.  On  most  pumps,  air  can  escape  by 

opening the oil filler plug/screw.

Model 

Number

Cylinder 

Capacity

(ton)

Stroke

(in)

Cylinder 

Effective 

Area       

(in

2

)

Oil 

Capacity

(in

3

)

Collapsed 

Height   

(in)

Extended 

Height      

(in)

Weight

(lb.)

Internal 

Pressure 

at 

Capacity

(psi)

Cylinder 

base

Dim.

(in)

Ram

Plunger

Dia.

(in)

Mouting 

Hole

Dia.

(in)

6CF05T03

5

0.24

1.10

0.26

1.26

1.50

1.3

9,090

2.4x1.6

0.98

0.20

6CF10T05

10

0.43

2.36

1.01

1.69

2.12

3.3

8,470

3.3x2.2

1.50

0.28

6CF20T05

20

0.43

4.38

1.88

2.01

2.44

2.9

9,130

4.0x3.0

2.00

0.40

6CF30T05

30

0.51

6.49

3.31

2.31

2.82

9.7

9,240

4.6x3.8

2.50

0.40

6CF50T05

50

0.63

9.86

6.21

2.64

3.27

14.9

10,140

4.5x4.5

2.76

0.43

SPECIFICATIONS

4

Содержание 6CF05T03

Страница 1: ...e safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Leer comprender y seguir las instr...

Страница 2: ...ds The user ultimately must make the decision regarding suitability of the product for any given task and therefore accept responsibility for that decision Immediately after lifting loads must be supp...

Страница 3: ...attempt to grasp a leaking pressurized hose Ensure to release the system pressure before disconnecting hydraulic hose or connections Hydraulic fluid can ignite and burn Keep hydraulic equipment away...

Страница 4: ...e connections must be free of dirt and grime Any equipment attached to the cylinder must be kept clean Figure 2 Illustration to bleed air from system Storage Cylinders should be stored with ram plunge...

Страница 5: ...ed the system Remedy overload condition Contact service center Cylinder move slower than normal Loose connection or coupler Restricted hydraulic line or fitting Pump not working correctly Cylinder sea...

Страница 6: ...1 N A Base 1 2 N A Plunger 1 3 H24 3 2828 100 Return Spring Assy 1 4 644 1 0060 200 Bolt 1 5 Dust Seal 1 6 H24 5 1804 206 Upper Bearing 1 7 Back Up Ring 1 8 O Ring 1 9 H24 5 0730 208 Bearing 1 10 Bol...

Страница 7: ...1804 103 H24 6 1804 109 Upper Bearing 1 8 N A N A Base 1 9 532 3 0060 100 532 3 0060 100 Special Washer 1 10 649 1 0060 040 649 1 0060 040 Bolt 1 11 H02 4 6003 108 H02 4 6003 108 Dust Cap Assembly 1 1...

Страница 8: ...sequence To ensure safe and reliable performance replace worn or damaged parts with Williams authorized repair parts only J H Williams Tool Group 6969 Jamesson Road Midland GA 31820 1 866 460 7995 RE...

Страница 9: ...In the unlikely event that a Williams product fails due to material defect in workmanship you may contact J H Williams Tool Group for disposition In such cases the customer s sole and exclusive remed...

Страница 10: ...10 Notes J H Williams Tool Group 6969 Jamesson Road Midland GA 31820...

Страница 11: ...11 Notes J H Williams Tool Group 6969 Jamesson Road Midland GA 31820...

Страница 12: ...12 Notes J H Williams Tool Group 6969 Jamesson Road Midland GA 31820...

Отзывы: