background image

3

PRODUCT   FEATURES

SAFETY  DEVICE

A    standard    requirement  for  all  vent-free    room
heaters, this  heater has a pilot  with  an  Oxygen
Depletion    Sensor(ODS)    safety    shutoff    system.
The  ODS/pilot    shuts    off    the  heater    if    there    is
not  enough  fresh  air.

PIEZO  IGNITION  SYSTEM

This    heater    is    equipped    with    a    piezo    ignitor.
This    system    requires    no    matches,  batteries,  or
other  sources  to  light  heater.

THERMOSTATIC  HEAT

CONTROL  ON  THERMOSTAT

MODELS  

These    heaters    have    a    control    valve    with    a
thermostat    sensing    bulb.  This    results    in    the
greatest    heater    comfort    and    may    result    in
lower  gas  bills.

LOCAL  CODES

Install  and  use  heater  with  care. Follow  all  local
codes. In  the  absence  of  local  codes, use   the
latest  edition  of  

National  Fuel  Gas  Code  ANSZ223.1

,

also  known  as  NFPA  54*.
*Available  from :
         American  National  Standards Institute, Inc.

1430  Broadway

         New York, NY 10018

National  Fire  Protection  Association, Inc.

 Batterymarch  Park 

Quincy, MA  02269

 

 

 

UNPACKING

1.   Remove  heater  from  carton.
2.   Remove  all  protective   packaging  applied  to
      heater  for  shipment.
3.    Check  heater  for  any  shipping  damage. If  heater
      is  damaged,  promptly  inform  dealer  where  you
       bought  heater.

Figure1-Vent-Free   Natural   Gas  Heater

Water  vapor  is  a  by-product  of  gas  combustion. An 

unvented  room  heater  produces  approximately  one  (1) 

ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of 

gas input per hour. 

Unvented room heaters are recommended as supplemental 

heat (a room) rather than a primary heat source (an entire 

house). In most supplemental heat applications, the water 

vapor does not create a problem. In most applications, 

the water vapor enhances the low humidity atmosphere 

experience during cold weather. 

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

The following steps will help insure that water vapor 

does not become a problem.

1.  Be  sure  the  heater  is  sized  properly  for  the 

application,  including  ample  combusion  air  and 

circulation air.

2. If  high humidity is experienced, a dehumidifier may 

be used to help lower the water vapor content of the air.

3. Do not use an unvented room heater as the primary 

heat source.

Содержание 2696541

Страница 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Страница 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Страница 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Страница 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Страница 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Страница 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Страница 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Страница 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Страница 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Страница 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Страница 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Страница 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Страница 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Страница 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Страница 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Страница 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Страница 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Страница 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Страница 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...