background image

10

Figure 14-Equipment  Shutoff  Valve

INSTALLATION 

CHECKING GAS  

CONNECTIONS  

   

WARNING: 

  

Test  all  gas piping   

and    connections    for    leaks  after                

installing  or  servicing.   Correct   all  

leaks   at   once. 

 

     

WARNING:   

Never    use    an  

open   flame   to   check   for   a   leak. 

Apply   a   mixture  of   liquid   soap 

and   water   to  all   joints.  Bubbles  

forming show  a  leak.  Correct  all   

leaks  at  once. 

 

Pressure  Testing  Gas  Supply   

Piping  System  

Test  Pressures  In  Excess  Of  

1/2  PSIG  (3.5 K Pa)  

1.   Disconnect   appliance   with   its     

       appliance       main        gas     valve  

     (control valve)   and   equipment  

      shutoff    valve   from   gas   supply  

        piping    system.    Pressures    in       

       excess  of   1/2  psig  will  damage  

      heater  regulator.  

2.    Cap   off  open   end   of   gas  pipe 

where  equipment  shutoff  valve 

      was   connected.  

3.   Pressurize  supply  piping     system  

by  either using  compressed   air or  

opening main  gas  valve  located  

on  or  near  gas  meter.

4.   Check  all  joints  of  gas  supply 

piping  system.  Apply  mixture  of 

liquid  soap  and  water  to  gas 

joints.  Bubbles    forming    show           

      a  leak.  

5.   Correct  all  leaks  at  once.  

6.   Reconnect heater and equipment   

       shutoff  valve  to  gas supply.  Check  

reconnected   fittings  for  leaks.

Test    Pressures    Equal    To  or 

Less  Than  1/2  PSIG  (3.5 K Pa)  

1.      Close  equipment    shutoff    valve 
       (see Figure 13).  
2.   Pressurize  supply  piping  system    
       by  either  using  compressed  air  
      or   opening    main    gas   valve      
      located  on  or  near  gas  meter.
3.   Check  all  joints  from  gas  meter     
      to  equipment  shutoff  valve  (see   
      Figure   14).   Apply    mixture   of          
       liquid  soap and water to  gas joints.  
      Bubbles  forming show a leak.   
4.   Correct  all  leaks  at  once.  

Pressure  Testing  Heater  Gas 

Connections  

1.    Open    equipment    shutoff    valve 
      (see  Figure  14).  
2.   Open main  gas  valve  located  on  
      or  near gas  meter.
3.   Make    sure    control    knob    of   
      heater  is  in  the  OFF position.  
4.   Check  all  joints  from  equipment  
      shutoff   valve   to   control   valve 
      (see  Figure 15 ).  Apply  mixture  of 
      liquid   soap    and    water  to   gas 
        joints.  Bubbles    forming    show            
      a  leak.  
5.   Correct all leaks at once.  
6.  Light    heater    (see   Operating
      Heater,  pages  10,11  and  12)      
     Check   the  rest  of  the   internal  
      joints  for  leaks.  
7.   Turn  off  heater (see  To  Turn  Off 
      Gas  to  Appliance,  pages 11 and 

12) .

8.   Replace  lower  front  panel.

OPERATING YOUR HEATER

FOR YOUR SAFETY

  

READ BEFORE LIGHTING  

A.  When  lighting  the  pilot,  follow  
      these  instructions  exactly.  
B.    BEFORE    LIGHTING    smell    all 
     around   the  appliance  area  for 
     gas.  Be  sure  to  smell  next  to 
      the  floor  because  some  gas  is 
     heavier  than  air  and  will  settle  
      on the  floor .  

Figure 15 -Checking  Gas  Joints

            WARNING:   

If  you  do  

not     follow   these  instructions  
exactly, a   fire   or   explosion  
may  result causing property dam-
age personal   injury or loss of  life.  

                  WARNING:     

Do  not 

over  tighten  gas  connections. 

WHAT TO DO  IF YOU SMELL GAS  

 

Do  not  try  to  light any  appliance.  

 

Do not touch any electric switch;    

        do  not  use  any  phone  in  your   
       building.  

 

Immediately       call      your     gas         

        supplier  from    a    neighbor’s 
       phone.     Follow        the        gas 
       supplier’s   instructions.  

 

If     you     cannot    reach    your  gas

        supplier,  call  the  fire  department.

  

C.  Use  only  your  hand  to  push  in 
     or  turn  the   gas   control  knob. 
     Never   use   tools.  If   the   knob 
        will    not    push    in    or    turn    by 
      hand, don’t  try  to  repair  it, call 
          a  qualified  service  technician  or 
      gas supplier. Force or attempted 
        repair  may  result  in    a  fire  or 
       explosion.  
D.    Do  not  use  this  appliance  if  any 
      part  has  been  under  water.  
        Immediately    call    a  qualified    
        service  technician      to      inspect 
      the  appliance   and   to   replace 
      any  part  of  the  control  system 
        and  any  gas  control  which  has 
       been  under  water.  

Содержание 2696541

Страница 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Страница 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Страница 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Страница 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Страница 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Страница 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Страница 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Страница 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Страница 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Страница 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Страница 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Страница 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Страница 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Страница 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Страница 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Страница 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Страница 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Страница 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Страница 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...

Отзывы: