PAGE 83 OF 98
NIGHT SCAN VERTICAL
OPERATING INSTRUCTIONS
TP-4836201-G
MARCH 2021
1,06
Well Open (vertical with
well cover) - Switch
State Error
Switch outputs are O.K.,
but show wrong polarity
for closed state
Well cover open or
wiring error. System is
expecting the well cover
to be closed at power-up
1,07
Microprocessor Error
No successful poll /
response
communication for
250ms
Defective processor on
the board
1,08
Internal firmware
detected error
Internal state machine
logic has detected an
invalid state transition.
Firmware logic error
1,09
Initiate Pushbutton input
error
Initiate input has
remained active for 5
seconds. Input is stuck,
or has been hot-wired
1. Unit is in NFPA mode
and connected to a Non-
NFPA J-box. (Note: if the
unit is in Non-NFPA
mode and connected to
an NFPA junction box,
the unit will look normal
(UP led on HHRC on),
but will not respond to
the HHRC. The software
is expecting to see the
init signal always on. No
error message is
generated).
2. Wiring short in the
control cable or
defective switch/wiring
1,10
Memory Error
Memory Error
Memory Error
1,11
Actuator current has
unexpectedly stopped
During decline, the Base
board senses actuator
current. After the "Near
0°" sensor is detected, it
is expecting to see the
current level rise before
it stops. This error
indicates the sensed
current has stopped
before nesting
If it occurs near the
nested position:
Actuator has reached its
internal stop before
nesting completed, most
likely saddle too low or
saddle not secured
causing sideways
movement when nesting
Table 9-1 Error and Warning Codes for Base Board (Continued)
Message
Meaning
Root Issue
Potential Cause
Содержание NIGHT SCAN VERTICAL
Страница 2: ......
Страница 6: ...PAGE 4 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 14: ...PAGE 12 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 16: ...PAGE 14 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 26: ...PAGE 24 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 52: ...PAGE 50 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 58: ...PAGE 56 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 73: ...PAGE 71 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 74: ...PAGE 72 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 75: ...PAGE 73 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 76: ...PAGE 74 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 77: ...PAGE 75 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 78: ...PAGE 76 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 80: ...PAGE 78 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 81: ...PAGE 79 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 82: ...PAGE 80 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 94: ...PAGE 92 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 98: ...PAGE 96 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...
Страница 100: ...PAGE 98 OF 98 NIGHT SCAN VERTICAL OPERATING INSTRUCTIONS TP 4836201 G MARCH 2021 ...