16
Connect Gas Cylinder
1. Make sure control knobs are “OFF” position.
2. The regulator rubber hose and regulator are properly and securely connected.
3. The regulator handle is in the “OFF” position. (Figure C).
4. Remove the seal cap from the automatic valve on the gas cylinder.
5. Place regulator onto the automatic valve on the gas cylinder. Push the black button down under the regulator valve
handle firmly and vertically. (Figure B).
6. You should hear a “click’’ sound when the regulator is securely latched.
CAUTION:
Never attempt to connect regulator when the regulator valve is not in the “OFF” position.
Operating Regulator
1. To turn regulator ON, turn the regulator valve counterclockwise into the “ON’’ position. (Figure D).
CAUTION:
If you unable to turn the regulator handle to the “ON’’ position, your regulator is not properly connected. Do
not force the handle to open. Remove the regulator and repeat “Connect Gas Cylinder” section.
2. To turn regulator OFF, turn the regulator valve clockwise into the “OFF” position. (Figure C).
Disconnect Gas Cylinder
1. Make sure control knobs are “OFF” position.
2. Turn the regulator handle in the “OFF” position. (Figure C).
3. Push the black button under the regulator valve handle down firmly and vertically, then pull the regulator upwards.
(Figure E).
CAUTION:
Never attempt to disconnect regulator when the regulator valve is not in the “OFF” position.
Operation of Excess Flow Check Device
The regulator can be fitted a safety device designed to automatically limit the gas escape in case of gas leak, which
prevents the gas from reaching the grill. The marking ‘’excess flow” on the regulator identification label means that the
regulator is provided with this option.
The “excess flow device” is likely to activate under the following condition
Normal operating conditions: Consumption of the gas fired appliance is higher that the regulator flow capacity. In such
case, you should contact your installer.
In case of pipe being torn off, proceed as follows:
1. Disconnect the regulator per the “Disconnect Gas Cylinder” section.
2. Re-fit the hose correctly
3. Connect the regulator per the “Connect Gas Cylinder” section.
4. Turn the regulator valve to the “ON” position.
5. Wait a few seconds (20 seconds) before restarting the system.
To guarantee a proper operation of the excess flow device, the pipe that supplier gas to the consuming appliance shall
be no more than 1.5 meters in length.
WARNING:
The regulator is
NEVER
to be left on the cylinder without its being connected to the grill, as the tear-off
proof safety is not designed to ensure the operation of the cylinder valve.