INSTALLATION, COMMISSIONING AND START-UP

 

 

 

 

Installation 

 
The unit should be installed by a qualified person and in accordance local area standards and regulations. 
Mains input requirements are detailed on the equipment data plate. 

Once fitted to a suitable mains supply make the connection of the hose for the conveyance of the fumes. 
It is advisable to protect the unit from moisture. 

 

WARNINGS 

Before installation, check there is a suitable mains supply. 

 

Commissioning 

 

It is recommended to include the use of the device subject to the following environmental conditions: 

-

 

The ambient operating temperature of the machine is between -10 ° C and 60 ° C 

-

 

The humidity of the indoor environment in which the work is carried out must be between 0% and 90% 

 

Recommendations / Instructions: 

-

 

The elimination/removal of any waste materials should be carried out according to the regulations 

-

 

For cleaning or replacing the filters using the mask and protective gloves. 

 

ATTENTION: 

 

Both containers and metal structures connected to it should be properly grounded as required by safety 
regulations. Do not operate the machine without grounding. 
 

Starting 

 

After carrying out the above checks, turn on the unit with the switch on the panel and position the collector 
hose near the pollutant source.

 

 

FUNCTIONING 

 

 

 

Description 

Normal use 

 

The F-Tech Pocket has been designed and built for intermittent use. 
The cleaner should be used exclusively for mechanical exhaust of smoke, fine dust, gas, gaseous pollutants 
in low concentrations through the torch hood or hose. Remember that: the law allows recycling in the 
environment only in case of occasional welding operations. The manufacturer is not liable for any use other 
than as described. 

DO NOT 

-

 

Remove the air cleaner filter panels 

 

-

 

In general, do not dismantle or remove any part of the unit when it is in use or connected to the mains 
supply

 

-

 

Do not trap the power cord. 

 

-

 

Do not tamper with the components of the electrical panel

 

-

 

Do not run the vacuum cleaner when the suction nozzle closed

 

-

 

Do not use the unit to pick up liquids

 

-

 

Do not place hot objects into the unit (e.g. cigarette butts)

 

Содержание F-TECH POCKET

Страница 1: ...F TECH POCKET Page 1 of 20 Aerservice S r l 2019 all rights reserved Reproduction in whole or in part is not allowed F TECH POCKET INSTRUCTION MANUAL FOR USE AND MAINTENANCE...

Страница 2: ...ion Manual 4 Glossary and pictograms 4 Manufacturer s identification data 7 Machine identification and data plates 8 Declarations 8 Warranty activation 10 USE AND GENERAL CHARACTERISTICS 11 FEATURES 1...

Страница 3: ...cording to the regulations in force carefully read the content of this Operating Manual and ensure that operators and maintenance staff operating and working on the machine read the relevant parts Thi...

Страница 4: ...ists some terms which are not commonly used or with a meaning different from the common one The meaning of the abbreviations and pictograms used is described below The abbreviations and pictograms are...

Страница 5: ...eration described in an optimal way as established by a careful manufacturer analysis whereby a different number of operators might not make it possible to obtain the expected result or might endanger...

Страница 6: ...hing of upper limbs Danger of entanglement Danger of being dragged by machine parts General hazard Danger of entanglement in transmission belt Hot surfaces danger of burning Danger of being dragged by...

Страница 7: ...ation data MANUFACTURER Aerservice Equipments S r l REGISTERED OFFICE ADMINISTRATIVE OFFICE Via Marconi 1 Z I 35020 Legnaro PD Italy EXCLUSIVE WHOLSALE UK IMPORTER Wilkinson Star Limited Shield Drive...

Страница 8: ...hnical assistance centres must refer to the said data The position of the plate on the machine may vary GENERAL INFORMATION Description 3 Declarations The machine is manufactured in conformity with re...

Страница 9: ...10 8 EC of the European Parliament and Council of 26 February 2014 on the approximation of the laws of the member States relating to electromagnetic compatibility Directive 2014 35 EU of the European...

Страница 10: ...F TECH POCKET Page 10 of 20 Aerservice S r l 2019 all rights reserved Reproduction in whole or in part is not allowed GENERAL INFORMATION Description 4 Warranty activation...

Страница 11: ...the purifier resistant to accidental impacts due to the use and to the movement The unit is also equipped with a convenient handle for ease of transport A filter section comprising a pre filter in met...

Страница 12: ...h occurs the separation of the particulates dust present in welding After this first stage of separation the air passes through the fan first and then passes through a panel with activated carbon for...

Страница 13: ...0V 110V Suction arm N 1 Supply voltage V 230 110 Mains frequency Hz 50 Installed power kW 1 1 Absorbed current A 4 85 9 30 Maximum extractor fan flow rate m3 h 250 Extractor fan negative pressure Pa 2...

Страница 14: ...ng the filters using the mask and protective gloves ATTENTION Both containers and metal structures connected to it should be properly grounded as required by safety regulations Do not operate the mach...

Страница 15: ...TIONING Description 3 Risks and emergencies Risks Description hazards and specific protections The manufacturer has taken steps to reduce the dangers that can arise due to incorrect use of the machine...

Страница 16: ...ing the retaining clips 2 Remove and clean the spark arrester material 3 Unscrew the locking knob 5 of the cartridge 4 and then remove it To clean it apply a jet of air in the opposite direction to th...

Страница 17: ...of the filters The maintenance intervals recommended periodic maintenance are listed below GROUP TO CHECK FREQUENCY OF CONTROL OPERATIONS TO DO Decanting container door When checking the filters Empt...

Страница 18: ...e process This operation should always be made in compliance with current local regulations If the equipment or part of it has been put out of service its parts must disposed of in a way that that doe...

Страница 19: ...ription 1 Details of maintenance operations The following table must be completed by a competent trained person It is of fundamental importance to keep these notes up to date in order to have an affec...

Страница 20: ...KET Page 20 of 20 Aerservice S r l 2019 all rights reserved Reproduction in whole or in part is not allowed Wilkinson Star Limited Shield Drive Wardley Industrial Estate Worsley Manchester M28 2WD 016...

Отзывы: