07 

 

 

 

 

 

 

 

4 OPERATING INSTRUCTIONS 

 

Place machine as far away from where cutting takes place as possible. Use all of the 6m torch length. This is 
to prevent the fumes produced  by  cutting from  being sucked  into  machine by  the  cooling fans through the 
front and side ventilation openings. 
 

BEFORE CUTTING 

The  operator  may  start  up  the  machine  only  after  having  read  and  understood  all  parts  of  this  manual.

 

Depending on the type of cut to be performed he must follow the work phases described below. 
 

WARNING! 

A preflow of 2 seconds after pressing the torch button to alert the operator of the 

imminent start of the pilot arc

 
1.

 Ensure that the work environment and your clothing satisfy the safety requirements described. 

2. 

Position the unit in a place where there is no obstruction to air circulation. 

3. 

Connect the unit to a suitable power socket (an earthed socket is obligatory).  

4

. Connect the compressed air pipe to the air filter on the rear panel. 

5. 

Ensure that there is no water in the air filter. If necessary, empty the filter. 

    NOTE!  Air  filter  is  a  semi-automatic  drain.

 

Semi-automatic  drain  operates  when  the  air  line  is 

depressurised.  When  the  filter  is  pressurised,  the  drain  can  still  operate  manually  by  pushing  the 
tube in the filter, which then protrudes outside the filter bowl. 
6.

 

Return clamp must be clamped into the work piece or cutting table. The area must be free from oil, paint 

and rust. Connect only to the main part of the work piece; do not connect to the part to be cut off. 
 

 

 
FRONT PANEL DESCRIPTION 

 
 
 
 

Air presence LED 

Reset Protection alarm LED  

Excess temperature LED 

Welding enabled LED 

Machine Live LED 

Cutting current regulation 

Air test button 

RESET button 

 
 
 

Содержание UNITOR UPC 310 ML

Страница 1: ...01 Instruction manual UPC 310 ML Air Plasma Cutter...

Страница 2: ...02 Revision summary Rev No Version Date issued 00 6938700000 April 18 2018...

Страница 3: ...onnected directly to the machine 3 Return clamp with 6m cable with Dix25 4 Initial supply consumables kit of 2 x Electrode 2 x Tip Drag 1 x Cartridge 5 Air regulator with filter and water separator mo...

Страница 4: ...void having any type of fuel with you such as cigarette lighters or matches The cutting sparks can cause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELE...

Страница 5: ...utting containers of potentially inflammable material These containers must be completely cleaned before they are cut ventilate the potentially inflammable area before using the machine do not use the...

Страница 6: ...ement or repair must be performed by a qualified person at an approved service centre EARTHING To ensure user protection the Inverter must by law be correctly connected to the earth system INTERNATION...

Страница 7: ...where there is no obstruction to air circulation 3 Connect the unit to a suitable power socket an earthed socket is obligatory 4 Connect the compressed air pipe to the air filter on the rear panel 5 E...

Страница 8: ...e RESET button 8 The red led 2 is now off and you are ready to cut If the RESET button is not pressed the unit will remain on STAND BY mode THIS IS A SAFETY DEVICE 1 The Inverter is now ready for work...

Страница 9: ...work piece 5 when cutting is established pull the torch slowly across the surface of the work piece 6 pause briefly at the and of the cut before releasing the trigger 7 The plasma arc goes out immedi...

Страница 10: ...h is activated DAILY INSPECTION AND REPLACEMENT CONSUMABLE TORCH PARTS Inspect and if necessary change the torch consumable parts Electrode and nozzle must be changed at regular intervals as a general...

Страница 11: ...lows 1 Remove the casing slackening the side screws 2 Remove all traces of dust from the internal parts of the machine by means of a jet of dry compressed air at a pressure no higher than 3 bar 3 Visu...

Страница 12: ...still the led 3 is on this is an indication that one of the PC Boards is possibly faulty See service instruction section manual DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT Do not dispose of electr...

Страница 13: ...I2 115V 25A 1torch SL100 Fe C Pressure 4 8 bar Flow 90 l min 230V 1 Phase 30A 115V 1 Phase 25A Thickness Cutting Speed Note Thickness Cutting Speed Note mm mm min mm mm min 12 100 Sever 12 50 Sever 1...

Страница 14: ...14 9 WIRING DIAGRAM...

Страница 15: ...30L 620359U0 61133100 61223600 620293U0 61133100 66078500 60155500 633164 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 _ _ _ _ _ _ Knob Front label Front panel support Potentiometer PCB Front panel...

Страница 16: ...ndard in force within the EEA has been used in the design EN 60974 1 2012 Ed 4 Arc welding equipment Part 1 Welding power sources EN 60974 10 2014 Ed 3 Arc welding equipment Part 10 Electromagnetic co...

Страница 17: ...17...