Wilhelmsen UNITOR UPC 310 ML Скачать руководство пользователя страница 5

05 

 

 

 

 

 

 

 

 

PREVENTION OF BURNS  

To protect your eyes and skin from burns and ultraviolet rays: 
- wear dark glasses. Wear suitable clothing, gloves and footwear. 
- use masks with closed sides, having lenses and protective glass according to standards (degree of 
protection DIN 10). 
- warn people in the vicinity not to look directly at the arc. 

 
PREVENTION OF FIRE 

Plasma cutting produces splashes of molten metal. 
Take the following precautions to prevent fire: 
- ensure that there is a fire extinguisher in the welding area. 
- remove all inflammable material from the immediate vicinity of the welding area. 
- cool the cut material or let it cool before touching it or putting it in contact with combustible material 
- never use the machine for cutting containers of potentially inflammable material. These containers must be 
completely cleaned before they are cut. 
- ventilate the potentially inflammable area before using the machine. 
- do not use the machine in atmospheres containing high concentrations of powders, inflammable gases or 
combustible vapours. 
 

2 TECHNICAL DATA 

 

Power supply 

230V ±15% 1~50/60 Hz 

115V +15%/-10% 1~50/60 Hz 

Mains fuse minimum (Slow 
blow) 

230V: 16A 
115V: 20A 

Maximum power 

230V: 2kVA 

115V: 1,3kVA 

Process power 

86V – 15A 
92V – 30A 

Air supply 
NB! Dry and oil free 

5-5,5 bar 
100 l/min 

Duty cycle @ 40° 

20% @30A 

60% @ 18A 

100% @ 16A 

Power factor 

0,99 

Open circuit voltage 

250V 

Protection class 

IP 23 

Environmental conditions 

Cutting: -10°C + 40°C 

Transport and storage: -20°C + 55°C 

Cooling 

Forced 

Temperature class 

Dimensions L x W x H 

430x160x350 mm 

Weight 

15,4 kg 

Severance cut 

230V: 12 mm 
115V: 12 mm 

Quality cut 

230V: 10 mm 

115V:  8 mm 

Recommended cut 

230V: 8 mm 

115V:  6 mm 

 
 

Содержание UNITOR UPC 310 ML

Страница 1: ...01 Instruction manual UPC 310 ML Air Plasma Cutter...

Страница 2: ...02 Revision summary Rev No Version Date issued 00 6938700000 April 18 2018...

Страница 3: ...onnected directly to the machine 3 Return clamp with 6m cable with Dix25 4 Initial supply consumables kit of 2 x Electrode 2 x Tip Drag 1 x Cartridge 5 Air regulator with filter and water separator mo...

Страница 4: ...void having any type of fuel with you such as cigarette lighters or matches The cutting sparks can cause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELE...

Страница 5: ...utting containers of potentially inflammable material These containers must be completely cleaned before they are cut ventilate the potentially inflammable area before using the machine do not use the...

Страница 6: ...ement or repair must be performed by a qualified person at an approved service centre EARTHING To ensure user protection the Inverter must by law be correctly connected to the earth system INTERNATION...

Страница 7: ...where there is no obstruction to air circulation 3 Connect the unit to a suitable power socket an earthed socket is obligatory 4 Connect the compressed air pipe to the air filter on the rear panel 5 E...

Страница 8: ...e RESET button 8 The red led 2 is now off and you are ready to cut If the RESET button is not pressed the unit will remain on STAND BY mode THIS IS A SAFETY DEVICE 1 The Inverter is now ready for work...

Страница 9: ...work piece 5 when cutting is established pull the torch slowly across the surface of the work piece 6 pause briefly at the and of the cut before releasing the trigger 7 The plasma arc goes out immedi...

Страница 10: ...h is activated DAILY INSPECTION AND REPLACEMENT CONSUMABLE TORCH PARTS Inspect and if necessary change the torch consumable parts Electrode and nozzle must be changed at regular intervals as a general...

Страница 11: ...lows 1 Remove the casing slackening the side screws 2 Remove all traces of dust from the internal parts of the machine by means of a jet of dry compressed air at a pressure no higher than 3 bar 3 Visu...

Страница 12: ...still the led 3 is on this is an indication that one of the PC Boards is possibly faulty See service instruction section manual DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT Do not dispose of electr...

Страница 13: ...I2 115V 25A 1torch SL100 Fe C Pressure 4 8 bar Flow 90 l min 230V 1 Phase 30A 115V 1 Phase 25A Thickness Cutting Speed Note Thickness Cutting Speed Note mm mm min mm mm min 12 100 Sever 12 50 Sever 1...

Страница 14: ...14 9 WIRING DIAGRAM...

Страница 15: ...30L 620359U0 61133100 61223600 620293U0 61133100 66078500 60155500 633164 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 _ _ _ _ _ _ Knob Front label Front panel support Potentiometer PCB Front panel...

Страница 16: ...ndard in force within the EEA has been used in the design EN 60974 1 2012 Ed 4 Arc welding equipment Part 1 Welding power sources EN 60974 10 2014 Ed 3 Arc welding equipment Part 10 Electromagnetic co...

Страница 17: ...17...

Отзывы: