10
5 TORCH PARTS
DESCRIPTION
PRODUCT NUMBER
COMMENTS
TORCH HEAD FOR UPC-310ML
ELECTRODE FOR UPC-310ML
START CARTRIDGE FOR UPC-310ML
TIP DRAG CUTTING FOR UPC-310ML
SHIELD CUP BODY FOR UPC-310ML
TORCH WITH 6M CABLE FOR UPC-310ML
310333
310334
310335
310336
310337
310332
1 PCS
5 PCS
1 PCS
5 PCS
1 PCS
1 PCS
CONSUMABLE KIT FOR UPC-310ML
310338
ELECTRODE 5 PCS
TIP DRAG CUTTING 5 PCS
START CARTRIDGE 1 PCS
SHIELD CUP BODY 1 PCS
6 MANTAINANCE
This section describes basic maintenance procedures performable by operating personnel. No other
adjustments or repairs are to be attempted by other than properly trained personnel.
WARNING
Disconnect primary power at the source before disassembling the power supply, torch, or torch
leads. Frequently review the Important Safety Precautions at the front of this manual. Be sure the
operator is equipped with proper gloves, clothing, eye and ear protection. Make sure no part of the
operator’s body comes into contact with the workpiece while the torch is activated.
DAILY INSPECTION AND REPLACEMENT CONSUMABLE TORCH PARTS
Inspect and, if necessary, change the torch consumable parts. Electrode and nozzle must be changed at
regular intervals, as a general guideline
after 3 hours continues use, after 200 starts or about 75m cut at
500mm/min - 30A.
Replace the nozzle if the opening is deformed or clearly oversized. Failure to replace
worn nozzle or electrode in time will dramatically reduce the cutting capacity and eventually ruin the torch.
Carefully inspect the hose assembly and torch body with regard to any leak or damage.
NOTE
The shield cup holds the tip and the starter cartridge shield cup in place. Position the torch with the shield
cup facing out when the cup is removed.
NOTE
Slag build-up on the shield cup that cannot be removed may affect the performance of the system.
1. Unscrew and remove the shield cup from the torch
2. Inspect the cup for damage. Wipe it clean or replace if damaged
3. Removed the tip. Check for excessive wear (indicated by an elongated or oversize orifice, see images).
Clean or replace the tip if necessary.
4. Remove the starter cartridge. Check for excessive wear plugged gas holes, or discolouration. Check the