Song Meter SM4BAT FS User Guide
3 Setup and Installation
Wildlife Acoustics, Inc.
page
17
3.12
Replacing the Clock Battery
A separate button cell CR2032 lithium battery maintains real-time clock settings
when the four main D batteries are being exchanged or are no longer
operational. The included battery should last up to 3 years. Use the steps below
to replace the internal clock battery.
1.
Open the security cover and the
middle section to access the
battery bay.
2.
Locate the circular
CLOCK
BATTERY
bay behind the
display and keypad opposite the
main battery bay.
3.
Gently insert a flathead screwdriver to pry the old
battery out.
4.
Slide a new battery under the two pins on the top
side with the CR2032 lettering facing you.
5.
Push down on the lower side until you feel the
battery seat.
3.13
Reading the Recorder Temperature
The recorder includes an integrated temperature sensor to log temperatures
inside the enclosure. This is intended for diagnostics only. Heat from the
electronics and/or sunlight on the enclosure can significantly increase the
temperature reading above ambient air conditions.
Press the
CHECK STATUS
button to view the current temperature reading.
Содержание Song Meter SM4BAT FS