3.4
Connecting External Power
With the optional external power cable, the power connector can accept
voltages from 5-17 volts DC. It is intended for 6 or 12-volt external batteries.
CAUTION
: If you are unfamiliar with configuring external battery and power systems,
consult a local installer for assistance.
1.
Each power cable is shipped with a
snap-on ferrite to meet standards
limiting electromagnetic emissions
and protecting against electrostatic
discharge. Install the ferrite near the
end of the cable as close to the
recorder as possible.
2.
Loop the cable through and snap
the ferrite shut. A zip tie is included
for further securing the ferrite. The
image shows the ferrite as shipped (right) and as installed (left).
3.
Align and seat the cable into the
EXT POWER
port on the side of the
recorder. Turn the grey locking ring (black on older SM3 cables) clockwise
P
firmly until it locks into place.
4.
The external power cable includes F2-size spade connectors and ring
terminals. Connect the cable to a 6 or 12-volt battery using one of the
connectors provided. The SM4BAT FS provides protection against accidental
reverse polarity connections.
5.
Open the security cover and slide the power switch up to
EXT
.
6.
(Optional) Set a minimum voltage to prevent damage to lead-acid batteries
that are not designed for deep discharge.