5.0 Servicing the Appliance.
The following procedures can and should
only
be performed by a
Gas Safe registered installer
.
This appliance should be serviced annually by a
Gas Safe registered installer
.
Servicing
SERVICING
INSTRUCTIONS
Remove the 2 screws securing the gas inlet access hatch, marked ‘
A
’ and the 4 screws securing
the burner tray to the firebox, marked ‘
B
’
5.1 Removal of the burner tray.
The removal and replacement of all the gas carrying components will require the removal of the
burner tray. The following informaon details the removal of this tray. Once removed, refer to
the relevant secon that follows detailing the removal of the specific component (s).
Turn off the gas supply at the isolaon valve on the appliance. Ensure the appliance is cold.
Remove the glass door. See page 6.
Remove the fuel effect components - put in a suitable locaon where they cannot be
damaged.
Disconnect the gas supply from the restrictor elbow.
Remove the screws securing the burner tray to the firebox
Disconnect the HT lead and unplug the switch harness.
Re-assemble the tray in the reverse order.