background image

 

23 

INSTALLATION 

INSTRUCTIONS

 

3.9 

This appliance has 4 different installaon methods: 

 

 
When the appliance is installed 

in  front 

of the heatproof board (or slips) on the wall or 

in 

front 

of the fireplace back panel then the 

Ravel 800 Edge Trim 

supplied with the appliance 

should be 

removed

 and 

discarded

.  The wider 

Ravel  800  Standard  Trim 

will be required - 

this will affix with magnets. 
 
When  the  appliance  is  installed  with  the  flange  of  the  appliance  concealed 

behind

  the 

heatproof board (or slips) or fireplace back panel then the 

Ravel  800  Edge  Trim 

(supplied) 

will be used. 
 
The diagrams below show the installaon of the appliance in all 4 of these configuraons. 

Methods of 

installation 

1. Heatproof board 

or 

2. Back panel 

3. Heatproof board 

or 

4. Back panel 

RAVEL 800 

EDGE TRIM 

RAVEL 800 

standard TRIM 

Содержание RAVEL 800CF

Страница 1: ...It is also the responsibility of the installa on engineer to ensure that the customer is Model number F 121XX2 SLIDE For use on Natural Gas G20 at a supply pressure of 20 mbar in GB Do not use this a...

Страница 2: ...stalla on Op onal 20 3 9 Installa on Methods 23 3 9 1 Edge Trim Installa on 24 3 9 2 Edge Trim Back Panel Requirements 25 3 9 3 Standard Trim Installa on 26 3 9 4 Standard Trim Back Panel Requirements...

Страница 3: ...er gas appliances are running on full rate mbar Complete relevant sec on of warranty forms ensure it is complete with Gas Safe registra on details Instruct the customer on ligh ng maintenance and serv...

Страница 4: ...y discolour or scorch Do not place or throw rubbish or otherwise on the fuel bed Do not place any combus ble materials or ooring i e carpets etc on any part of the hearth Many parts of this appliance...

Страница 5: ...empts check the baLery see page 6 If the baLery is new and the pilot s ll fails to light contact a gas safe engineer Once the pilot is lit keep the lever pushed to the le for up to 10 seconds then rel...

Страница 6: ...ning or to access the ceramic logs and pilot area for maintenance The special Allen key supplied with the appliance should be used to release the two door clasps features at the top of the door Insert...

Страница 7: ...te The fuel e ect components supplied with this product are extremely fragile and must be handled with great care The ceramics in this appliance are not covered by the warranty due to their fragility...

Страница 8: ...e worse where wooden oors are present as lint is more free to move on these areas Pet hair can also cause this problem Using a thin nozzle on a vacuum cleaner this area can be cleaned to remove any li...

Страница 9: ...the frequency will be depend upon use See page 6 for glass door removal and installa on The fuel bed setup involves the installa on of volcanic rock ceramic bark ember wire and a boxed set of ceramic...

Страница 10: ...loose about 20mm wide and as long enough to cover the volcanic rock then align over the rock as shown Ensure no wire is placed within 25mm of the pilot assembly Retain the other half of the wire for...

Страница 11: ...he main log as shown Place Log E in the orienta on shown Check that the charcoal area of this log sits just above the air hole as shown in the picture Align the peak of log E with the pit on the edge...

Страница 12: ...RUCTIONS Place the bark around the fuel bed as shown Ensure that no bark can interfere with the pilot opera on Place Log G as shown in the picture Place Log F onto the burner bed in front of the centr...

Страница 13: ...13 USER INSTRUCTIONS Place Log H onto the burner bed as shown Place Log I onto the burner bed as shown...

Страница 14: ...year limited guarantee is managed directly by Hearth Products Ltd With our experienced Gas Safe engineers and through our extensive network of service centres throughout the UK we will ensure your app...

Страница 15: ...o the replace opening The Ravel 800 Edge Trim is supplied with the appliance The Ravel 800 Standard Trim is an op onal extra There will be four plas c bags also located in the carton Instruc ons and g...

Страница 16: ...lt is 74 7 net 67 3 gross This e ciency value has been veri ed by Kiwa 0558 This e ciency value can be used for SAP Standard Assessment Procedure for energy ra ng of UK dwellings Appliance Technical I...

Страница 17: ...vious installa on was intended for solid fuel it must be swept prior to this installa on proceeding Typical installa ons will use the rear exit ue for 7 diameter unlined chimneys However this applianc...

Страница 18: ...liner or to 5 ue pipe this is not required ventilation 3 5 No purpose made ven la on is required for this product as the nominal input does not exceed 7 0 kW however if spillage is detected during the...

Страница 19: ...the rebox should be insulated to prevent heat loss with a layer of mineral wool insula on or similar The appliance must stand on a non combus ble surface with a minimum thickness of 12mm The cavity vo...

Страница 20: ...circumstances should a liner be used in any other type of installa on The following diagrams show the step by step process of conver ng the appliance to top vent and securing the liner to the rebox Re...

Страница 21: ...optional Now remove the four screws and take o the top cover plate Next t the ue closure plate with the 3 screws provided NOTE THIS PART CAN ALSO BE FITTED FROM THE INSIDE OF THE APPLIANCE THEN THE LO...

Страница 22: ...l the liner downwards and locate the studs into the correct posi on Note that by rota ng the spigot through 180o the centre line can be moved fore and a by 30mm This may be required to help clear repl...

Страница 23: ...d The wider Ravel 800 Standard Trim will be required this will a x with magnets When the appliance is installed with the ange of the appliance concealed behind the heatproof board or slips or replace...

Страница 24: ...e removed to allow for screw xings 3 on each side The diagrams below show these knockout posi ons The side knockouts allow the xing of the two side wings Fit the two side wings as shown below Note the...

Страница 25: ...ALLATION INSTRUCTIONS EDGE TRIM INSTALLATION 3 9 2 When the Ravel 800 Edge Trim op on is selected the following diagram shows the back panel slip set dimensions which should be used Cri cal Mantel Dim...

Страница 26: ...crews provided to secure the trim to the brackets Removal of the Standard trim requires the removal of these 2 screws Then simply liJ the trim o the support brackets Hang the trim on the brackets as s...

Страница 27: ...TION INSTRUCTIONS Standard TRIM INSTALLATION 3 9 4 When the Ravel 800 Standard Trim op on is selected the following diagram shows the back panel slip set dimensions which should be used Cri cal Mantel...

Страница 28: ...gh the two small holes at the top rear of the appliance pass each cable through the two holes as shown this will secure the cable Thread the cable through the eyebolts and back into the appliance When...

Страница 29: ...w Fixing The appliance can be installed using the screw xings supplied See the diagrams below The foam seal which is supplied with the appliance should be a xed to the rear face of the INSTALLATION IN...

Страница 30: ...void Before connec ng the gas supply to the appliance the supply should be purged to ensure no debris can enter the appliance and a gas soundness test should be performed to ensure that the exis ng pi...

Страница 31: ...31 Connecting To gas supply INSTALLATION INSTRUCTIONS Remove the ceramic pad using the nger slot provided Remove the heat shield plate...

Страница 32: ...sconnect the HT Lead from the electrode on the pilot Only if tray is to be removed for cable xing Disconnect the black switch harness plug socket Only if tray is to be re moved for cable xing Fit isol...

Страница 33: ...uency will be depend upon use See page 6 for glass door removal and installa on The fuel bed setup involves the installa on of volcanic rock ceramic bark ember wire and a boxed set of ceramic decora v...

Страница 34: ...it loose and about 20mm wide then align over the volcanic rock as shown Ensure no wire is placed within 25mm of the pilot assembly Retain the other half of the wire for replacement at annual service...

Страница 35: ...lace Log C onto the right raised burner as shown ensuring it ts securely INSTALLATION INSTRUCTIONS Place Log E in the orienta on shown Check that the charcoal area of this log sits just above the air...

Страница 36: ...k around the fuel bed as shown Ensure that no bark can interfere with the pilot opera on Place Log G as shown in the picture Place Log F onto the burner bed in front of the centre burner as shown INST...

Страница 37: ...37 Place Log H onto the burner bed as shown Place Log I onto the burner bed as shown INSTALLATION INSTRUCTIONS...

Страница 38: ...l to provide a spark at the electrode it may be that a small amount of soot has fallen from the fuel bed onto the pilot assembly causing a short circuit If this is the case ensuring the appliance is o...

Страница 39: ...smoke match about 50mm into the gap a the top centre of the re Traverse the match across the length of the dra diverter All the smoke must be drawn into the ue If spillage occurs allow a further 5 min...

Страница 40: ...e room If the shelf projects more than 150mm then the distance between the top of the appliance and the underside of the shelf must be increased accordingly for every 10mm of projec on above 150mm the...

Страница 41: ...ronted gas appliances will leave condensa on on the inside face of the glass when rst lit this is perfectly normal and is a result of the water vapour present in the combus on products hiBng the cold...

Страница 42: ...re the removal of the burner tray The following informa on details the removal of this tray Once removed refer to the relevant sec on that follows detailing the removal of the speci c component s Turn...

Страница 43: ...43 SERVICING INSTRUCTIONS Remove the ceramic pad using the nger slot provided Remove the heat shield plate Fit isola on valve to the inlet pipe as shown below...

Страница 44: ...44 SERVICING INSTRUCTIONS Disconnect the HT Lead from the electrode on the pilot Disconnect the black switch harness plug socket Carefully remove the burner tray from the rebox...

Страница 45: ...45 SERVICING INSTRUCTIONS 5 2 Remove of Slide Gas Valve Remove the pilot tube Remove 1 screw to remove the heat shield...

Страница 46: ...the gas inlet tube nut and the main burner gas outlet nut The valve can now be removed serviced or replaced SERVICING INSTRUCTIONS 5 2 Remove of Slide Gas Valve con nued When reassembling the valve e...

Страница 47: ...nut Remove the pilot gas supply nut the thermocouple nut from the valve and the 2 screws as shown in the diagram below 5 4 Remove of spark generator Remove the screw Detach the black and white connect...

Страница 48: ...l of the heat shield as shown Remove the 16 screws as shown in the diagram below to release all pipework from the underside of the burner tray Take care not to mix up the screws 4 x self tap silver sc...

Страница 49: ...Con nued Remove the gas inlet and gas outlet nuts then remove the two nuts securing the tee valve to the underside of the burner tray 5 6 Removal of Injectors Remove the 8 screws 4 each side as shown...

Страница 50: ...val of Injector Con nued The 4 injectors can be accessed using the socket drive Finally remove the screw as shown below The tee connector can be pulled out and the middle burner injector can be remove...

Страница 51: ...SERVICING INSTRUCTIONS 5 7 Removal of the Debris Access Cover Remove the 5 screws and the 3 nuts as shown in the diagram below to remove the access cover This will reveal the access for debris remova...

Страница 52: ...e Engineer Registra on No Date of annual service 6 0 Record of annual services The extended warranty of the speci ed components within this appliance is condi onal on the annual service of the applian...

Страница 53: ...Gas Safe Registered Installer Full details are provided in this manual Hearth Products Ltd Unit 14 Tollgate Industrial Estate Sta ord ST16 3SU Product Fiche Manufacturer Hearth Products Ltd Model No...

Страница 54: ...54 This page is inten onally le blank...

Страница 55: ...55 This page is inten onally le blank...

Страница 56: ...the customer The spares shop also features other components which may have to be installed by a Gas Safe engineer If in doubt please contact us directly Due to our policy of con nual product improveme...

Отзывы: