WILDEN PUMP & ENGINEERING, LLC
28
WIL-12320-E-05
W I L - G A R D ™ D I A P H R A G M S E N S O R
Step 2
Prior to installing the liquid chamber,
and after positioning the Wil-Gard™
sensor cable between the primary
and back-up diaphragms, run the
sensor cable along the diaphragm
bead but outside the pump. Now
install the liquid chamber and large
clamp band.
Step 3
When installing the liquid chamber
and large clamp band, route the Wil-
Gard™ sensor cable to the inside of
the large clamp band fastener. Next,
reconnect the Wil-Gard™ module.
NOTE: Use caution to ensure that
the sensor wires are not damaged
or pinched by the clamp band.
Wil-Gard™ Diaphragm Sensor Installation
S W I V E L P U M P S T A N D O P T I O N
Draining Pump Contents
To drain the pump of its contents, first disconnect the inlet
and discharge connections. Next loosen the anti-rotation bolt
(item #1) by turning counter-clockwise. Do not remove the
bolt; only loosen the bolt two turns. After loosening the anti-
rotation bolt, rotate pump 180°. This will allow the contents
within the pump to flow out of the discharge and into a suitable
container. After draining the pump, rotate the pump back to
the upright position and tighten the anti-rotation bolt.
Removing Pump From Swivel Pump Stand
Saniflo™ HS pumps are very heavy. It is recommended that
the pump be disassembled while attached to the stand. If it
is necessary to remove the pump from the stand while fully
assembled, use a hoist or mechanical means to support the
pump as it is removed from the stand.
To remove your Saniflo™ HS pump from the swivel pump
stand, first loosen the anti-rotation bolt (item #1) by turning
counter-clockwise. Next, ensure the entire pump weight is
supported by hoist and loosen the locking pin (item #2) by
turning counter-clockwise. This will allow the pump to be
removed from the stand.
CAUTION: Removal of the locking pin (item #2) will allow the
pump to fall from the stand, potentially causing injury to the
operator or personnel in the immediate area. Never operate
or store the pump without the locking pin (item #2) in place
and properly torqued.
NOTE: The center
block-to-bushing bolts
(item #4) attach the
center block mounting
bushing (item #3) to
the center block (not
shown). These bolts
do not need to be
removed to remove
the pump from the
stand.
NOTE: Torque values
are located in Section
7 of this manual.
For ease of maintenance and cleaning, Wilden offers an optional swivel pump stand. The swivel pump stand allows the
pump to be drained by rotating the pump so that the fluid can flow out of the discharge and into a suitable container.
Step 1
The Wil-Gard™ sensor wires
must be installed between the
primary diaphragm and the back-
up diaphragm, on both sides
of the pump, at the six o’clock
position. They should be positioned
approximately half the distance
to the shaft from the edge of the
diaphragm.
Swivel Pump Stand