S e c t i o n 5 B
S U C T I O N - L I F T C U R V E S
Suction-lift curves are calibrated for pumps operating
at 305 m (1,000') above sea level. This chart is meant
to be a guide only. There are many variables that can
affect your pump’s operating characteristics. The
number of intake and discharge elbows, viscosity of
the pumping fluid, elevation (atmospheric pressure)
and pipe friction loss all affect the amount of suction-
lift your pump will attain.
P X 1 5 S A N I F L O ™ HS
R E D U C E D - S T R O K E
S U C T I O N - L I F T C A PA B I L I T Y
P X 1 5 S A N I F L O ™ HS
F U L L - S T R O K E
S U C T I O N - L I F T C A PA B I L I T Y
PX15 HS Performance
19