Precautions - Read First!

 

 
 

TEMPERATURE LIMITS:

 

 

Acetal  

29°C to 82°C  

20°F to 180°F 

Buna-N  

12°C to 82°C  

10°F to 180°F 

Geolas

t® 

 

40°C to 82°C  

40°F to 180°F 

Neoprene  

18°C to 93°C  

0°F to 200°F 

Nordel

®

 EPDM  

51°C to 138°C  

60°F to 280°F 

Nylon  

18°C to 93°C  

0°F to 200°F 

PFA  

7°C to 107°C  

45°F to 225°F 

Polypropylene  

0°C to 79°C  

32°F to 175°F 

Polyurethane  

12°C to 66°C  

10°F to 150°F 

PVDF  

12°C to 107°C  

10°F to 225°F 

Saniflex™ 

 

29°C to 104°C  

20°F to 220°F 

SIPD PTFE with EPDM-backed  

4°C to 137°C  

40°F to 280°F 

SIPD PTFE with Neoprene-
backed  

4°C to 93°C  

40°F to 200°F 

PTFE

1

  

4°C to 104°C  

40°F to 220°F 

FKM  

40°C to 177°C  

40°F to 350°F 

Wil-

Flex™ 

 

40°C to 107°C  

40°F to 225°F 

 

1

 4°C to 149°C (40°F to 300°F) - 

13 mm (1/2”) and 25 mm (1”) models only

.

 

NOTE: 

Not all materials are available for all models. Refer to Section 2 for 

material options for your pump. 

 

CAUTION: 

When choosing pump materials, be sure to 

check the temperature limits for all wetted components. 

Example: PTFE has a maximum limit of 104°C (220°F) but 

polypropylene has a maximum limit of only 79°C (175°F). 

 

CAUTION: 

Do not apply compressed air to the exhaust ports 

 pump will not function. 

 

CAUTION : 

Do not over-lubricate air supply 

 excess 

lubrication will reduce pump performance. Pump is pre-lubed 

with NLGI Grade 2 white EP grease. 

 

CAUTION: 

Maximum temperature limits are based upon 

mechanical stress only. Certain chemicals will significantly 

reduce maximum safe operating temperatures. Consult 

engineering guide for chemical compatibility and 

temperature limits. 

 

CAUTION: 

Always wear safety glasses when operating 

pump. If diaphragm rupture occurs, material being 

pumped may be forced out air exhaust. 

 

WARNING:

 Prevention of static sparking 

 If static 

sparking occurs, fire or explosion could result. Pump, 

valves, and containers must be properly grounded when 

handling flammable fluids and whenever discharge of 

static electricity is a hazard. 

NOTE: 

Do not exceed 6.9 bar (100 psig) air supply 

pressure for P1500 polypropylene pumps. 

 

CAUTION: 

Do not exceed 8.6 bar (125 psig) air 

supply pressure for P1500 PVDF pumps. 

 

CAUTION: 

Before any maintenance or repair is 

attempted, the compressed air line to the pump should 

be disconnected and all air pressure allowed to bleed 

from pump. Disconnect all intake, discharge and air 

lines. Drain the pump by turning it upside down and 

allowing any fluid to flow into a suitable container. 

 

CAUTION: 

Blow out air line for 10 to 20 seconds 

before attaching to pump to make sure all pipe line 

debris is clear. Use an in-

line air filter. A 5μ (micron)

 

air filter is recommend. 

 

NOTE: 

When installing PTFE diaphragms, it is 

important to tighten outer pistons simultaneously 

(turning in opposite directions) to ensure tight fit. 

 

WARNING: 

Tighten all bolts and retainers prior to 

installation. Fittings may loosen during transportation. 

 

NOTE: 

Before starting disassembly, mark a line from each 

liquid chamber to its corresponding air chamber. This line 

will assist in proper alignment during reassembly. 

 

CAUTION: 

Verify the chemical compatibility of the 

process and cleaning fluid to the pump’s component

 

materials in the Chemical Resistance Guide. 

 

CAUTION: 

When removing the end cap using 

compressed air, the air valve end cap may come out with 

considerable force. Hand protection such as a padded 

glove or rag should be used to capture the end cap. 

 

CAUTION: 

Pump is not rated for U.L. 79 service.  

For 

U.L. 79 transfer use Wilden’s U.L.

-approved  

T Series pump. 

 

NOTE: 

The elbows and tees have bosses that are 

designed to be tapped with a 9.5 mm NPT (3/8”)

 

fitting for draining the pump during maintenance. 

 

CAUTION: 

The P1500 pump is not submersible. 

 

 

 

Section 1 

Содержание PRO-FLO P1500

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE P1500 Bolted Plastic Pump WIL 11160 E 09 Where InnovationFlows...

Страница 2: ...tion 5 Performance 8 P1500 Plastic Reduced Stroke PTFE Fitted 8 P1500 Plastic Full Stroke PTFE Fitted 8 Suction Lift Curves 9 Section 6 Suggested Installation Operation 10 Maintenance and Troubleshoot...

Страница 3: ...ifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regist...

Страница 4: ...parking occurs fire or explosion could result Pump valves and containers must be properly grounded when handling flammable fluids and whenever discharge of static electricity is a hazard NOTE Do not e...

Страница 5: ...Most Elastomeric materials use colored dots for identification NOTE Not all models are available with all material options P1500 ADVANCED PLASTIC 76 mm 3 Pump Maximum Flow Rate 878 lpm 232 gpm Section...

Страница 6: ...nd manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump di...

Страница 7: ...IA 0 6 DIA N 150 5 9 FLANGES DIN mm ANSI inch P 160 DIA 6 0 DIA R 191 DIA 7 5 DIA S 18 DIA 0 8 DIA LW0404 REV A DIMENSIONS ITEM METRIC mm STANDARD inch A 914 36 0 B 160 6 3 C 694 27 3 D 1278 50 3 E 18...

Страница 8: ...formance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P1500 PLASTIC FULL STROKE PTFE FITTED ShipWeight Polypropylene 138 kg 305...

Страница 9: ...g at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables which can affect your pump s operating characteristics The number of intake and discharge elbows viscos...

Страница 10: ...alves should be used This valve allows trapped air between the valve and the pump to bleed off which improves pump performance Pumping volume can be estimated by counting the number of strokes per min...

Страница 11: ...e volume and or pressure of the air supply to the pump An air regulator is used to regulate air pressure A needle valve is used to regulate volume Pump discharge rate can also be controlled by throttl...

Страница 12: ...ve spool to be unable toshift 7 Remove plug from pilot spoolexhaust Pump runs but little or no product flows 1 Check for pump cavitation slow pump speed down to allow thick material to flow into liqui...

Страница 13: ...ss fluid The Wilden P1500 has a 76 mm 3 inlet and outlet and is designed for flows up to 878 lpm 232 gpm Its air distribution system is based on a revolutionary design which increases reliability and...

Страница 14: ...intake manifold from liquid chambers and center section to expose intake valve balls and seats Inspect the ball cage area of manifold for excessive wear or damage Repeat Steps 4 6 NOTE Two people or...

Страница 15: ...ich remains connected to the opposite side diaphragm assembly Figure 10b Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemi...

Страница 16: ...nects the air supply to the center section Proprietary composite seals reduce the coefficient of friction and allow the P1500 to run lubefree Constructed of polypropylene the Pro Flo air distribution...

Страница 17: ...etaining O rings on both sides of center section with O ring pick Step 7 Remove air chamber bolts with 3 4 hex socket Step 8 Remove pilot spool bushing from center block Step 9 Gently remove pilot spo...

Страница 18: ...hamber Air Chamber 3 4 N m 32 ft lb Figure A NSTALLATION The following tools can be used to aid in the installation of the new seals Needle Nose Pliers Phillips Screwdriver Electrical Tape Wrap electr...

Страница 19: ...WIL 11160 E 09 Wilden 19 Exploded View and Parts Listing P1500 PLASTIC AIR DISTRIBUTION SYSTEM EXPLODED VIEW Section 8...

Страница 20: ...Gasket Air Valve 1 15 2615 52 15 2615 52 8 Nut Square 7 16 14 6 15 6506 03 15 6506 03 9 Center Block Assembly 2 1 15 3110 20 15 3110 20 10 Removable Pilot Sleeve Assembly 1 15 3882 99 15 3882 99 11 S...

Страница 21: ...WIL 11160 E 09 Wilden 21 Exploded View and Parts Listing P1500 PLASTIC LIQUID PATH EXPLODED VIEW...

Страница 22: ...55 15 1085 55 11 Ball Cage 4 15 5350 20 15 5350 21 15 5350 20 15 5350 21 12 Screw HH 3 4 10 x 8 3 8 24 15 6192 03 15 6192 03 15 6192 03 15 6192 03 13 Washer 3 4 812 x 1 750 x 095 48 15 6735 03 15 673...

Страница 23: ...WIL 11160 E 09 Wilden 23 Notes...

Страница 24: ...nd Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modifythe information and illustrations contained in this document without...

Отзывы: