WIL-10330-E-04
21
WILDEN PUMP & ENGINEERING, LLC
Step 9A
Due to varying torque values, one
of the following two situations
may occur: 1) The outer piston,
diaphragm and inner piston remain
attached to the shaft and the entire
assembly can be removed from the
center section.
Step 9B
2) The outer piston, diaphragm and
inner piston separate from the shaft
which remains connected to the
opposite side diaphragm assembly
(Figure 9B). Repeat disassembly
instructions for the opposite liquid
chamber. Inspect diaphragm
assembly and shaft for signs of
wear or chemical attack. Replace
all worn parts with genuine Wilden
parts for reliable performance.
Step 10
To remove diaphragm assembly
from shaft, secure shaft with soft
jaws (a vise fi tted with plywood,
plastic, or other suitable material)
to ensure shaft is not nicked,
scratched or gouged. Using
an adjustable wrench, remove
diaphragm assembly from shaft.
The name says it all.
Noise reduction in the workplace is critical to enhanced productivity.
Realize the benefits of air-operated pump technology while providing a
safe and profitable environment for your employees with Sound Shield™.
• Avg. 14 dBA reduction
• No system modifications
• Strong & light weight
• Installs in minutes
P U M P D I S A S S E M B L Y