![Wilden HS400S Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/wilden/hs400s/hs400s_manual_980860007.webp)
S e c t i o n 5
P E R F O R M A N C E
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
HS400S ALUMIMUM
TPE-FITTED
Height ................................. 605 mm (23.8")
Width .................................. 343 mm (13.5")
Depth .................................. 320 mm (12.6")
Ship Weight ............................27 kg (60 lbs)
Air Inlet ................................... 19 mm (3/4”)
Inlet ...................................... 38 mm (1-1/2")
Outlet ................................... 38 mm (1-1/2")
Suction Lift ..........................1.1 m Dry (3.6')
9.0 m Wet (29.5')
Disp. per Stroke ............... 0.26 L (0.07 gal)¹
Max. Flow Rate .............. 227 lpm (60 gpm)
Max. Size Solids .................. 8.0 mm (5/16")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 45 lpm (12 gpm) against
a discharge head of 4.8 bar (70 psig) requires
4.1 bar (60 psig) and 59 Nm
3
/h (35 scfm) air
consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
WIL-11112-E-01
5
WILDEN PUMP & ENGINEERING, LLC
60
[102]
80
[136]
10 20 30 40 50 60
[38] [76] [114] [151] [189] [227]
40
[68]
20
[34]
120
psig
100
psig
80
psig
60
psig
40
psig
20
psig
250
200
150
100
50
100
0
0
2
4
6
8
10
12
14
16
200
300
400
500