Pump will not run.
1.  Check for pressurized air at the inlet.

2.  Check air inlet and filter for debris.

3.  Connect a test lamp to the two wires which run to pump 

and ensure that the lamp cycles on and off.

4.  Make sure that the air valve manual override (small red 

knob on front of valve) is switched to the “0” position.

5.  Check pilot pressure vent at the top of the operator/coil 

assembly to ensure that it is not clogged.

6.  Check for a worn out air valve. If air continually blows 

out the exhaust in very large quantities, the air valve 

seals may be worn beyond their ability to function. In 

this case, the valve must be replaced.

NOTE: Before the valve is scrapped, it is possible that it may 

be saved by completely disassembling the valve, cleaning all 

components and relubricating the valve.

Pump runs but little or no fluid comes out.
1.  Check that the discharge isolation valve is not closed.

2.  Check that the electronic signal is slow enough that the 

pump is able to complete each physical stroke before 

it is signaled to change direction. The time required to 

complete the stroke is determined by a variety of factors 

which include fluid viscosity and head pressure.

3.  Check for pump cavitation; slow pump speed down to 

match the thickness of the material being pumped.

4.  Check for sticking ball check valves. If the material being 

pumped is not compatible with the pump elastomers, 

swelling may occur. Replace ball check valves and  

O-ring with the proper elastomers.

5.  Check to make sure that all suction connections are air 

tight, and that the clamp bands are properly tightened.

Pump air passages blocked with ice.
Check for excessive moisture in compressed air line. As 

the air expands out the exhaust during the operation of the 

pump, water vapor entrapped in the compressed air can 

freeze and block the air passageways in the pump. If this 

occurs, it may be necessary to install a coalescing filter, an 

air dryer, or a hot air generator for the compressed air.

Air bubbles in pump discharge.
1.  Check for ruptured diaphragm.

2.  Check tightness of fasteners, and the integrity of the  

O-rings, especially at intake manifold.

Product comes out air exhaust.
1.  Check for diaphragm rupture.

2.  Check tightness of piston plates to shaft.

Pump rattles.
1.  Create false discharge head or suction lift.

Solenoid buzzes or solenoid burnout.
1.  Incorrect voltage, faulty or dirty solenoid.

Solenoid valve fails to shift electrically but shifts with 

manual override.
1.  Incorrect voltage, defective coil or wiring.

Solenoid valve fails to shift electrically or with manual 

override.
1.  Inadequate air supply, contamination, inadequate or 

improper lubrication, mechanical binding in the valve.

Valve shifts but fails to return.
1.  Broken spring, mechanical binding.

Excessive leaking from air valve vent.
1.  Worn seals in air valve.

T R O U B L E S H O O T I N G

Содержание A2 Original Plastic Series

Страница 1: ...W h e r e I n n o v a t i o n F l o w s www wildenpump com A2 Original Metal Pump EOM Engineering Operation Maintenance WIL 10060 E 03 REPLACES WIL 10060 E 02...

Страница 2: ...ies Center Section 10 SECTION 6 70 30 OPERATING CONDITION A2T Metal Rubber Fitted T series Center Section 11 A2T Metal PTFE Fitted T series Center Section 11 A2P Metal Rubber Fitted P series Center Se...

Страница 3: ...and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Before any maintenance or repair is attempted the compressed air line to th...

Страница 4: ...ED ALUMINUM PP POLYPROPYLENE AIR VALVE A ALUMINUM available on A2T only L ACETAL available on A2P AND A2B only P POLYPROPYLENE available on A2P AND A2B only U UHMW PE available on A2B only DIAPHRAGMS...

Страница 5: ...Liquid is free to move past the inlet valve ball and fill the liquid chamber see shaded area FIGURE 2 When the solenoid valve is deenergized the air valve redirects pressurized air to the back side o...

Страница 6: ...F L M N S P R G H J K DIMENSIONS ITEM METRIC mm STANDARD inch A 267 10 5 B 36 1 4 C 137 5 4 D 254 10 0 E 279 11 0 F 28 1 1 G 97 3 8 H 76 3 0 J 191 7 5 K 211 8 3 L 173 6 8 M 107 4 2 N 127 5 0 P 8 0 3...

Страница 7: ...E 13 mm 1 2 BSP FNPT AIR EXHAUST A B C D E G H J K L M N P R S T U V F 25 mm 1 BSP FNPT LIQUID INLET DIMENSIONS ITEM METRIC mm STANDARD inch A 267 10 5 B 36 1 4 C 124 4 9 D 254 10 0 E 279 11 0 F 28 1...

Страница 8: ...S E DIMENSIONS ITEM METRIC mm STANDARD inch A 267 10 5 B 36 1 4 C 137 5 4 D 254 10 0 E 267 10 5 F 295 11 6 G 41 1 6 H 97 3 8 J 76 3 0 K 191 7 5 L 211 8 3 M 173 6 8 N 107 4 2 P 127 5 0 R 8 0 3 S 43 1 7...

Страница 9: ...head pressure of 2 7 bar 39 psig requires 4 1 bar 60 psig and 17 9 Nm3 h 10 5 scfm air consumption See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure Height 279 mm 11 0 Width...

Страница 10: ...lpm 32 gpm Max Size Solids 3 2 mm 1 8 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 37 9 lpm 10 gpm against a dis...

Страница 11: ...I T I O N A 2 T M E TA L 7 0 3 0 O P E R AT I N G C O N D I T I O N A 2 P M E TA L 7 0 3 0 O P E R AT I N G C O N D I T I O N 5 10 15 20 0 50 100 150 200 250 300 350 400 450 500 18 9 37 9 56 8 75 7 GP...

Страница 12: ...ing rate Consult Section 6 for performance information The use of an air filter before the pump will ensure that the majority of pipeline contaminants will be eliminated For best results the pump shou...

Страница 13: ...n and service should be informed of any abnormalities that are detected during operation Internal maintenance is not recommended for Accu Flo solenoid air valves When worn or damaged a new air valve b...

Страница 14: ...ball check valves If the material being pumped is not compatible with the pump elastomers swelling may occur Replace ball check valves and O ring with the proper elastomers 5 Check to make sure that...

Страница 15: ...ld only be replaced with factory supplied parts TOOLS REQUIRED Adjustable Wrench 9 16 Box Wrench 3 4 Box Wrench 3 16 Hex Wrench Vise equipped with soft jaws such as plywood plastic or other suitable m...

Страница 16: ...ensure shaft is not nicked scratched or gouged Using a wrench remove diaphragm assembly from shaft Inspect all parts for wear and replace with genuine Wilden parts if necessary Step 5 Figure 5 Remove...

Страница 17: ...side and align center section with chamber using alignment marks made during disassembly Push down on diaphragm assembly until diaphragm is inverted Place opposite liquid chamber on center section an...

Страница 18: ...13 12 11 1 5 2 9 4 3 10 11 15 18 19 31 30 29 28 9 22 21 13 11 12 12 Adapter Block Version 32 PTFE Assembly NOTE PTFE Diaphragm Models Assembled with PTFE Gasket Kit At Factory Not Shown S e c t i o n...

Страница 19: ...N R N R 02 1060 51 02 1060 51 02 1060 51 02 1060 51 02 1060 51 22 Diaphragm 2 02 1010 55 02 1010 55 02 1010 55 02 1010 55 02 1010 55 23 Valve Balls 4 02 1080 55 02 1080 55 02 1080 55 02 1080 55 02 108...

Страница 20: ...15 14 13 12 14 16 3 2 1 11 18 18 27 28 20 25 26 35 36 37 17 16 19 17 10 5 4 6 7 6 8 9 Adapter Block Version PTFE Assembly NOTE PTFE Diaphragm Models Assembled with PTFE Gasket Kit At Factory Not Show...

Страница 21: ...3701 01 02 3751 01 02 3751 01 02 3751 01 02 3751 01 02 3751 01 22 Pistons Outer 2 02 4550 01 02 4550 01 02 4550 03 02 4550 04 02 4550 03 02 4550 01 02 4550 01 02 4550 03 02 4550 04 02 4550 03 23 Liqu...

Страница 22: ...UL CSA Voltage 10 Current A AC AC DC Power W DC Resistivity Part Number 60 Hz 50 Hz 10 Inrush Holding 00 2110 99 150 24 48 44 4 8 20 20 20 121 00 2110 99 151 12 24 22 4 8 40 40 40 32 00 2110 99 155 6...

Страница 23: ...mes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...

Страница 24: ...p PSG ADoverCompany PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document 01 2015 A u t h o r i z e d P...

Отзывы: