19
WIKA operating instructions pressure transmitter, model IS-3
EN
14243628.02 10/2018 EN/DE
3. Specifications
3.8 Operating conditions
ATEX/IECEx ignition protection
types (see product label)
■
II 1G Ex ia IIA T4/T5/T6 Ga
■
II 1G Ex ia IIC T4/T5/T6 Ga
■
II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb
■
II 3G Ex ic IIC T4/T5/T6 Gc X
■
II 3G Ex nA IIC T4/T5/T6 Gc X
■
II 3D Ex tc IIIC T90 °C Dc X
■
II 1D Ex ia IIIC T135 °C Da
■
II 1/2D Ex ia IIIC T135 °C Da/Db
■
I M1 Ex ia I Ma
Ingress protection (per
IEC 60529)
The ingress protection depends on the respective electrical connection.
The stated ingress protection only applies when plugged in using mating connectors
that have the appropriate ingress protection.
■
Angular connector DIN EN 175301-803 A:
IP65
■
Circular connector M12 x 1 IEC 61076-2-101 A-COD:
IP67
■
Circular connector M16 x 0.75 IEC 61076-2-106
IP67
■
Cable outlet IP67:
IP67
■
Cable outlet IP68 cable gland:
IP68
1)
■
Cable outlet IP68 (permanent use in the medium):
IP68
2)
■
Cable outlet IP67 with protection cap:
IP67
3)
■
Bayonet connector MIL-DTL-26482:
IP67
■
Field case:
IP69K
1) 72 h / 300 mbar
2) Maximum pressure of the surrounding medium: 2 bar
3) Precondition: Avoidance of water accumulation in the protection cap
Vibration resistance
(per IEC 60068-2-6, vibration
under resonance)
■
Model IS-3: 20 g
■
Model IS-3 with field case and cable outlet IP67 with protection cap: 10 g
■
Model IS-3 with measuring range >1,000 bar: 5 g
■
Model IS-3 for optional medium temperature ranges: 5 g
■
Model IS-3 for optional medium temperature ranges and with field case: 2 g
Содержание IS-3
Страница 58: ...58 WIKA operating instructions pressure transmitter model IS 3 14243628 02 10 2018 EN DE EN ...
Страница 110: ...110 WIKA Betriebsanleitung Druckmessumformer Typ IS 3 14243628 02 08 2018 EN DE DE Anlage 1 Konformitätserklärung ...
Страница 115: ...115 WIKA Betriebsanleitung Druckmessumformer Typ IS 3 DE 14243628 02 08 2018 EN DE ...