l
AI
(
PA
-
OUT
)
l
T
emperature
l
A
dditional
C
yclic
V
alue
Byte-No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Format
Value
IEEE-754-
Flieskommazahl
PA-OUT
(FB1)
Status
Status
(FB1)
IEEE-754-
Flieskommazahl
Temperature
(FB2)
IEEE-754-
Flieskommazahl
Additional Cyclic
Value
Status
Status
(FB2)
Status
Status
F
ig
.
17
:
T
elegram con
fi
guration example
1
E
xample
2
with pressure value and temperature value without additional cyclical value
:
l
AI
(
PA
-
OUT
)
l
T
emperature
l
F
ree
P
lace
Byte-No.
1
2
3
4
5
6
7
8
9
10
Format
Value
IEEE-754-
Flieskommazahl
PA-OUT
(FB1)
Status
Status
(FB1)
IEEE-754-
Flieskommazahl
Temperature
(FB2)
Status
Status
(FB2)
F
ig
.
18
:
T
elegram con
fi
guration example
2
E
xample
3
with pressure value and additional cyclical value without temperature value
:
l
AI
(
PA
-
OUT
)
l
F
ree
P
lace
l
A
dditional
C
yclic
V
alue
Byte-No.
1
2
3
4
5
6
7
8
9
10
Status
Status
Status
Status
(FB1)
IEEE-754-
Floating point value
PA-OUT
(FB1)
IEEE-754-
Floating point value
Additional Cyclic
Value
Format
Value
F
ig
.
19
:
T
elegram con
fi
guration example
3
P
rocess pressure transmitter
IPT
-
10
V
ers
.
2
.
0
-
ceramic sensor
•
P
ro
fi
bus
PA
49
10
S
upplement
31541
-
EN
-
110418
Содержание IPT-10