![WIKA IPT-10 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/wika/ipt-10/ipt-10_operating-instructions-manual_980481029.webp)
I
nformation
:
F
or an adjustment with pressure
,
simply enter the actual measured
value indicated at the bottom of the display
.
I
f the adjustment ranges are exceeded
,
the message
"
O
utside
parameter limits
"
appears
.
T
he editing procedure can be aborted with
[
ESC
]
or the displayed limit value can be accepted with
[
OK
]
.
T
his function enables reading out parameter adjustment data as well
as writing parameter adjustment data into the sensor via the indicating
and adjustment module
.
A
description of the function is available in the
operating instructions manual
"
I
ndicating and adjustment module
"
.
T
he following data are read out or written with this function
:
l
M
easured value presentation
l
A
djustment
l
D
amping
l
L
inearisation curve
l
S
ensor
-
TAG
l
D
isplayed value
l
S
caling unit
(
O
ut
-
S
cale unit
)
l
P
ositions after the decimal point
(
scaled
)
l
S
caling
PA
/
O
ut
-
S
cale
4
values
l
U
nit of measurement
l
L
anguage
T
he following safety
-
relevant data are
not
read out or written
:
l
S
ensor address
l
PIN
l
A
pplication
C
opy sensor data
C
opy sensor data
?
B
asic settings
I
f the
"
R
eset
"
is carried out
,
the sensor resets the values of the
following menu items to the reset values
(
see chart
):
7
)
M
enu section
F
unction
R
eset value
B
asic settings
S
ensor address
126
Z
ero
/
M
in
.
adjustment
M
easuring range begin
S
pan
/
M
ax
.
adjustment
M
easuring range end
D
ensity
1
kg
/
l
D
ensity unit
kg
/
l
7
)
S
ensor
-
speci
fi
c basic adjustment
.
C
opy sensor data
R
eset
P
rocess pressure transmitter
IPT
-
10
V
ers
.
2
.
0
-
ceramic sensor
•
P
ro
fi
bus
PA
29
6
S
et up with the indicating and adjustment module