![WIKA F3201 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/wika/f3201/f3201_operating-instructions-manual_980137012.webp)
12
WIKA operating instructions, model F3201
EN
79101735.01 08/2021 EN/DE
5. Commissioning, operation
5. Commissioning, operation
5.1 Mounting precaution
■
Shear beams are sensitive measuring instruments and must be handled with appropriate
care.
■
Before installing the shear beam, check whether the mounting position have been
executed dimensionally accurately, thus guaranteeing problem-free mechanical
fixation of the shear beam.
■
It must be ensured that there is no force shunt between the contact surface of the
transducer and the force introduction. The measuring spring must also be free of
force shunts in the area of the force introduction under rated load. A gap of at least
0.5 mm must be provided.
■
Before installation, make sure that the drilling chips have been removed from the
holes.
■
Depending on the installation situation, lubricant may be required in the holes for
mounting the shear beam.
■
In the area of the contact surface of the shear beam, an even surface must be
ensured.
■
Depending on the installation situation and the availability of mechanical mounting
kits, holes must be drilled.
5.2 Mounting instructions
CAUTION!
Damage to the instrument through improper installation
■
Improper assembly can lead to improper loads on the shear beam due to torsional
and shear forces. These loads cause measured errors and can permanently damage
or destroy the shear beam.
■
Incorrect loading can lead to permanent damage resulting in a zero point offset in the
unloaded state.
■
Carry out the mounting of the shear beam without using strong force (e.g. hammer).
■
Do not use the shear beam as a climbing aid.
■
The force acting on the shear beam must be applied at the designated point in the
correct load direction.
■
Pay attention to the mounting instructions.
■
The output signal and the pin assignment are stated on the product label.
■
During mounting of the shear beam, the output signal (force value) must always be
monitored to avoid mechanical overload.
■
Avoid torsional torques, off-centre loads and transverse loads or lateral forces. Trans-
verse loads and lateral forces also include the corresponding components of the
measurands that are introduced slanted.
■
The shear beam may only be subjected to loads in the type of bearing provided.
Содержание F3201
Страница 1: ...Operating instructions Betriebsanleitung EN DE Model F3201 Shear beam model F3201 Scherstab Typ F3201...
Страница 22: ...22 WIKA operating instructions model F3201 EN 79101735 01 08 2021 EN DE Annex EU declaration of conformity...
Страница 39: ...39 WIKA Betriebsanleitung Typ F3201 DE 79101735 01 08 2021 EN DE 9 Technische Daten Abmessungen in mm...
Страница 42: ...42 WIKA Betriebsanleitung Typ F3201 DE 79101735 01 08 2021 EN DE Anlage EU Konformit tserkl rung...
Страница 43: ...43 WIKA Betriebsanleitung Typ F3201 DE 79101735 01 08 2021 EN DE...