Fig. 18 - Example of connections - 

Fig. 19 - Example of connections - 

 

 

1 – Fitting 
2 - Drain plug 
3 - Service valve 
4 - Piping 

5 -  Three piece fitting 
6 - Root valve with drain 
7 - Process piping 
8 - Three piece fitting 

9 - “T” fitting 
10 - Three piece fitting 
11 - Curve 
12 - Blocking joint 

13 - M6 screws (No. 4) 
14 - Bracket for 2” pipe 
15 - Vertical pipe 
16 - Horizontal pipe 

 

Annex 1 – Model code 

MODEL CODE 

AP     

 

 

 

 

 

 

 

For further information see 
datasheet 

 

 

 

 

 

   

 

 

     

 

           

 

 

 

 

1.1  Ignition protection mode 

 

 

                   

 

 

 

Weather proof 

 

 

 

 

                   

 

 

 

Ex d 

1.2  Sensor code 

 

 

 

  10               

 

 

 

Low absolute pressure 

 

 

 

 

 

  L               

 

 

 

Medium absolute pressure 

 

 

 

 

 

  H               

 

 

 

High absolute pressure 

1.5

 

Electric Contacts

 

 

 

 

 

 

  U         

 

 

 

One 

  

 

 

 

 

 

  D         

 

 

 

Two 

1.6

 

Type of Electric Contact

   

 

 

 

 

 

    N   

 

 

 

Silver 

  

 

 

 

 

 

 

    S   

 

 

 

 Argon sealed 

 

 

 

 

 

 

 

 

    G   

 

 

 

Gold 

 

 

 

 

 

 

 

 

    O   

 

 

 

Gold + Argon sealed 

 

 

 

 

 

 

 

 

    R   

 

 

 

Silver adjustable dead band 

1.7

 

Options

 

 

Example: Intrinsic Safety execution

 

 

 

  

 

 

 

 

 
 

12

/20

18

 W

IKA

 bas

e

on

 1

2/

2

016

 CE

LLA

 

Содержание APW SERIES

Страница 1: ...ions in mm Versions APW10 Versions APA10 A pressure attachment B cable entry WEIGHT 8 2 kg dimensions in mm A vacuum attachment B cable entry WEIGHT 10 kg dimensions in mm For surface mounting use fou...

Страница 2: ...otection against heat radiation fluid separators cooling coils heated lockers must be taken Process fluid or its solid particles must not however go inside instrument chambers 2 OPERATING PRINCIPLE Th...

Страница 3: ...1 Weatherproof pressure switches Models APW Remove the blocking device fixed to the side of the instrument case and the adjustment screw access plate fig 59 Remove the cover by rotating it in an anti...

Страница 4: ...brate the set point with an accuracy of 0 16 mbar 1 of the adjustable span Fig 6 Calibration circuit for instrument with adjustable range less than 60 mbar 1 Pressure switch 2 Test gauge 3 Inlet valve...

Страница 5: ...to the applicable standards In case of flameproof instrument see also the Standard IEC 60079 14 If the electrical connection is carried out in a protected tube it shall be made so that condensate is...

Страница 6: ...ere should be no trace of leakage of process fluid outside the instrument In case of flame proof or intrinsic safety instruments inspections of the electrical installation are to be carried out also a...

Страница 7: ...TION PROBABLE CAUSE REMEDY Set point shift Permanent deformation of the sensitive element due to fatigue or non tolerated overranges Variation of the elastic features of the sensitive element due to i...

Страница 8: ...fitting 10 Three piece fitting 11 Curve 12 Blocking joint 13 M6 screws No 4 14 Bracket for 2 pipe 15 Vertical pipe 16 Horizontal pipe Annex 1 Model code 1 MODEL CODE AP For further information see dat...

Отзывы: