EN
WIKA operating instructions attachable indicator model A-IAI-1
15
14016825.03 12/2018 EN/DE
6. Commissioning, operation
6. Commissioning, operation
6.1 Electrical connection
The connection of the attachable indicator is made via simply plugging it
between an existing transmitter and connector using a specific adapter
design for connectors to DIN 175301-803 A.
No separate power supply is needed since the instrument is powered directly
from the measuring current.
The connection and commissioning should only be carried out
by skilled, qualified personnel. An incorrect connection could
damage the indicator.
CAUTION!
Note the maximum permissible input current of 40 mA!
6.2 Pin assignment
The assignment of the angular connector is designed for the most common-
ly-used configuration for the respective input signal. Since this assignment
is not standardised, it can happen that the assignment for the connected
transmitter does not match the assignment of the attachable indicator.
Standard assignment for the model A-IAI-1 angular connector
Contact no.
Wiring colour Pin
Female connector
1
grey
1)
d
display -
2
red
connected
3
black
connected
4
yellow
connected
1) The wire between pin 1 and the device is blue, the wire between the device and female contact 1 is
grey. Only the grey wire can be changed.