![WIKA A-AI-1 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/wika/a-ai-1/a-ai-1_operating-instructions-manual_980177012.webp)
EN
WIKA operating instructions attachable indicator model A-IAI-1
12
14016825.03 12/2018 EN/DE
3. Specifications
Safety-related maximum values
Power supply
U
i
= DC 9 ... 28 V
Short circuit current
Ii = 100 mA
Power limitation
P
i = 1,200 mW
Maximum effective internal
capacitance
C
i
< 13 nF
Maximum effective internal
inductance
negligibly small
For further specifications see WIKA data sheet AC 80.07 and the order documen
-
tation.
WARNING!
For further important safety instructions for operation in hazard-
ous areas see chapter 2.3 "Additional safety instructions for
instruments per ATEX".
Dimensions in mm
Содержание A-AI-1
Страница 26: ...EN WIKA operating instructions attachable indicator model A IAI 1 26 14016825 03 12 2018 EN DE ...
Страница 50: ...WIKA Betriebsanleitung Aufsteckanzeige Typ A IAI 1 50 DE 14016825 03 12 2018 EN DE ...
Страница 51: ...WIKA Betriebsanleitung Aufsteckanzeige Typ A IAI 1 51 DE 14016825 03 12 2018 EN DE ...