14503941.01 11/2021 EN/DE/FR/ES
22
WIKA operating instructions models TR10-0, TC10-0 (FM, CSA)
EN
11.2 Model TC10-0
Measuring element
Type of measuring
element
Thermocouple per IEC 60584-1 or ASTM E230
Types K, J, E, N, T
Measuring current
■
Ungrounded welded (standard)
■
Welded to the bottom (grounded)
Validity limits of the class accuracy per EN 60584-1
Type K
Class 2
-40 ... +1.200 °C [-40 ... +2,192 °F]
Class 1
-40 ... +1.000 °C [-40 ... +1,832 °F]
Type J
Class 2
-40 ... +750 °C [-40 ... +1,382 °F]
Class 1
-40 ... +750 °C [-40 ... +1,382 °F]
Type E
Class 2
-40 ... +900 °C [-40 ... +1,652 °F]
Class 1
-40 ... +800 °C [-40 ... +1,472 °F]
Type N
Class 2
-40 ... +1,200 °C [-40 ... +2,192 °F]
Class 1
-40 ... +1,000 °C [-40 ... +1,832 °F]
Type T
Class 2
-40 ... +350 °C [-40 ... +662 °F]
Class 1
-40 ... +350 °C [-40 ... +662 °F]
Validity limits of the class accuracy in accordance with ASTM-E230
Type K
Standard
0 ... 1,260 °C [32 ... 2,300 °F]
Special
0 ... 1,260 °C [32 ... 2,300 °F]
Type J
Standard
0 ... 760 °C [32 ... 1,400 °F]
Special
0 ... 760 °C [32 ... 1,400 °F]
Type E
Standard
0 ... 870 °C [32 ... 1,598 °F]
Special
0 ... 870 °C [32 ... 1,598 °F]
Type N
Standard
0 ... 1,260 °C [32 ... 2,300 °F]
Special
0 ... 1,260 °C [32 ... 2,300 °F]
Type T
Standard
0 ... 370 °C [32 ... 698 °F]
Special
0 ... 370 °C [32 ... 698 °F]
For further specifications see WIKA data sheet TE 66.01 and the order documentation.
11. Specifications