15
3.2
Work to be carried out by the user
3.2.1 Calibrating the weighing equipment for WI-5000-T
1.
Put the weighing trestle at zero via net gross and zero.
2.
Then push and hold the net gross and on buttons simultaneously.
3.
Hold the net gross button pushed down until calib appears on the screen.
4.
Push the on button three times.
5.
Put a heavy object, the weight of which is known, onto the weighing trestle. For the best results, calibrate
the computer with at least the heaviest load you will use.
6.
Push the on button, and the value will start to blink.
7.
Enter the correct weight (the calibration weight) via the net gross and the tare buttons.
8.
Push the on button.
9.
The word good will appear on the screen.
10.
Push and hold the on button until end appears on the screen.
11.
Push the on button once again.
The weighing computer has now been calibrated.
Do not try and calibrate the weighing computer until the weight readings are stable. The calibration
procedure is not used for correcting instability, inconsistencies or flashing “RANGE” messages.
Figure 3.2.1-Control panel weighing computer
ATTENTION:
Zero adjustment-setting and calibration have been realised by the manufacturer.