![WIESHEU Ebo 124 S Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/wiesheu/ebo-124-s/ebo-124-s_original-installation-manual-and-operating-instructions_979915039.webp)
Page 39
Deck oven
6.3. Faults/causes/remedies
31
WARNING
Technical damage!
Remove the mains
plug if damaged!
Only use the device when it is in technically perfect condition.
Check the device for damage before starting any work.
All parts must be correctly installed and must fulfi l all condi-
tions to ensure faultless operation of the device. If you can
see damage, pull out the mains plug, mark the damage clearly
and set up a notice.
Symptom
Cause
Remedy
Water is in the bak-
ing chamber
1. Internal obstruction of control unit
2. Too much steaming (time/quantity)
3. Pressure regulator defective
4. Water pressure too high
5. Flow rate gauge dirty
6. Solenoid valve defective
1. Mains separation
2. Less steam
3. Customer service
4. Customer service
5. Customer service
6. Customer service
No steaming No
steam
1. Steam pipe / humidifying connection scaled
2. Water supply line not open
3. Dirt fi lter blocked
4. Hose kinked / clamped
5. Wrong program content
6. Solenoid valve defective
7. Hose connections defective
8. Steam button defective
9. Heating defective
10. Door not closed
1. Check
2. Check
3. Check
4. Check
5. Check
6. Customer service
7. Customer service
8. Customer service
9. Customer service
10. check
Oven is not heating
up
1. Temperature not set
2. Heater contactor defective
3. Heating defective
4. STL (chamber) has triggered
5. Chamber sensor defective
6. Door not closed
1. Check
2. Customer service
3. Customer service
4. Customer service
5. Customer service
6. check
Exhaust air valve
does not react
1. Valve defective (electrical)
2. Valve mechanically blocked
1. Customer service
2. Customer service
Oven cannot be
switched on
1. Internal blocking of the controller
2. No on-site power supply
3. STL (chamber) has triggered
4. Main fuse defective
5. ON switch/main switch defective
6. Internal fuse defective (power section)
7. Switch-on button defective
1. Disconnect mains
2. Check
3. Customer service
4. Customer service
5. Customer service
6. Customer service
7. Customer service