![WIESHEU Ebo 124 S Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/wiesheu/ebo-124-s/ebo-124-s_original-installation-manual-and-operating-instructions_979915022.webp)
Page 22
Deck oven
3.5 Distances
For information on the distances for setting up the combined installation, refer to the
set-up specifi cations from the individualinstallation plan
Ensure clear space beside, above and underneath the appli-
ance.
To prevent heat accumulation, place the appliance at least 50 mm
away from the wall.
The air vents on the sides and on the back must not be covered.
There must be suffi cient clear space of at least 200 mm above the
appliance. Additionally, we recommend not to cover the clear space
under the station.
With completely installed devices, the exhaust air must always be
vented forwards.
With series 124 / 128, you must observe the distances from the
custom installation guides. These distances must not be less than
100 mm to the side panel.
Min. 200 mm
Approx. 50 mm
Clear space in front of and behind the oven/station
For servicing purposes, the oven/station must be pushed for-
wards.
You must provide a free space in front of the system of at least
1000 mm. Electricity, water, waste water and exhaust connections
are located at the back of the appliance.
These must be accessible when required.
A minimum distance of 200 mm must be maintained at the rear.
Min. 200 mm