Light Diagnostics Table D10-8 & C10-8
Light
Led 1
Led 2
Led 3
Led 4
Led 5
Audible
Alert
Condition Action
System
Operation
Illuminated
FULLY
None
Unit is operating using POWER button
on panel, no remote signal
Illuminated
FULLY
Illuminated
FULLY
None
Unit is operating using remote signal
(or mc2 signal if provided)
Illuminated
FULLY
Fading
IN-OUT
None Shutdown
delay
(Remote /mc2 signal has been removed)
Flashing
Slowly
None
Unit is in Standby mode, waiting for
remote signal (or mc2 signal if
provided) to start unit
Using The POWER button while L5 is
Flashing SLOWLY will temporarily
disable any active remote standby.
To Re-Establish STANDBY turn the
unit off using the POWER button.
Low System
Pressure
Flashing
Quickly
Fading
IN-OUT
Fading
IN-OUT
Beep
Every
Second
Abnormally Low Pressure, Unit has or
Will Shut Down If Not Corrected
Check Motor(s), Check Motor Brushes,
Verify If Filters Are Installed,
Close All Filter Access Points
Service
Motors
Flashing
Slowly
Beep
Every 4
Hours
50 hrs of life left in brushes
Order brushes if not already on
hand.
If brushes on hand change now and
reset alert.
Flashing
Quickly
Beep
Every
15 Mins
30 hrs of life left in brushes
Unit Will SHUT DOWN In 30 Hours to
prevent motor damage
Flashing
Quickly
Beep
Every 5
Mins
10 hrs of life left in brushes
Unit Will SHUT DOWN In 10 Hours to
prevent motor damage
Flashing
Quickly
Illuminated
FULLY
Beep
Every
Second
Motor Brush Life Expired Unit Shut
Down
Replace ALL motor brushes.
Reset Brush Life Alert
See Video Link:
www.youtube.com/watch?v=LOm81obvaDE
Service
Filters
Flashing
Slowly
None
Filter Pressure High
Prepare To Replace/Service Filters
Flashing
Quickly
Beep
Every
Hour
Filter Pressure Close To Critical
Replace/Service Filters Now.
Continued Operation Will Result In
Unit Shutdown
Flashing
Quickly
Fading
IN-OUT
Beep
Every
Second
Critical Pressure, Unit Shut Down
Verify Blockage, Verify All Filters
Illuminated
FULLY
Beep
Every
Hour
Replace Filter (s) ASAP
Replace Filter (s) ASAP
Reset Filter Life Alert
See Video Link:
www.youtube.com/watch?v=LOm81obvaDE
Filter Auto
Clean
(iVac Only)
Illuminated
FULLY
Flashing
Slowly
None
Unit in operation & filters are
scheduled to be cleaned the next time
unit is shut off for more than 5
seconds
Flashing
Quickly
None
Unit is OFF, filter being cleaned
Illuminated
FULLY
Illuminated
FULLY
None
Unit in operation.
ALERT, filter cleaning motor not
operating at optimum
Replace Filter Cleaning motor
Fading
IN-OUT
OFF
None
Unit is in Constant AUTO Cleaning Mode
Vacuum Controlled By POWER Button On
Control Panel
Unit Automatically Shuts OFF
Vaccum , Cleans & The ReStarts
Vaccum
Fading
Illuminated
None
Unit is in Constant AUTO Cleaning Mode
Unit Automatically Shuts OFF