background image

 

 

 Light Diagnostics Table D10-8 & C10-8 

Light 

Led 1 

Led 2 

Led 3 

Led 4 

Led 5 

Audible 

Alert 

Condition Action 

System 

Operation 

Illuminated 

FULLY 

 

 

 

 

None 

Unit is operating using POWER button 

on panel, no remote signal 

 

 Illuminated 

FULLY 

   

Illuminated 

FULLY 

None 

 

Unit is operating using remote signal 

(or mc2 signal if provided) 

 

 Illuminated 

FULLY 

   

Fading 
IN-OUT 

None Shutdown 

delay 

(Remote /mc2 signal has been removed) 

 

      

Flashing 

Slowly 

None 

Unit is in Standby mode, waiting for 

remote signal (or mc2 signal if 

provided) to start unit 

Using The POWER button while L5 is 
Flashing SLOWLY will temporarily 

disable any active remote standby. 
To Re-Establish STANDBY turn the 
unit off using the POWER button. 

Low System 

Pressure 

Flashing 

Quickly 

Fading 
IN-OUT 

Fading 
IN-OUT 

  

Beep 

Every 

Second 

Abnormally Low  Pressure, Unit has or 

Will Shut Down If Not Corrected 

Check Motor(s), Check Motor Brushes, 

Verify If Filters Are Installed, 

Close All Filter Access Points 

Service 

Motors 

 Flashing 

Slowly 

   

Beep 

Every 4 

Hours 

50 hrs of life left in brushes 

Order brushes if not already on 

hand. 

If brushes on hand change now and 

reset alert. 

  

Flashing 

Quickly 

   

Beep 

Every 

15 Mins 

30 hrs of life left in brushes 

Unit Will SHUT DOWN In 30 Hours to 

prevent motor damage 

  

Flashing 

Quickly 

   

Beep 

Every 5 

Mins 

10 hrs of life left in brushes 

Unit Will SHUT DOWN In 10 Hours to 

prevent motor damage 

 Flashing 

Quickly 

Illuminated 

FULLY 

   

Beep 

Every 

Second 

Motor Brush Life Expired Unit Shut 

Down 

Replace ALL motor brushes.  

Reset Brush Life Alert 

See Video Link: 

www.youtube.com/watch?v=LOm81obvaDE 

Service 
Filters 

  

Flashing 

Slowly 

 

 

None 

Filter Pressure High 

Prepare To Replace/Service Filters 

  

 

Flashing 

Quickly 

  

Beep 

Every 

Hour 

Filter Pressure Close To Critical 

Replace/Service Filters Now. 

Continued Operation Will Result In 

Unit Shutdown 

 Flashing 

Quickly 

 Fading 

IN-OUT 

  

Beep 

Every 

Second 

Critical Pressure, Unit Shut Down 

Verify Blockage, Verify All Filters 

  

 

Illuminated 

FULLY 

  

Beep 

Every 

Hour 

Replace Filter (s) ASAP 

Replace Filter (s) ASAP 
Reset Filter Life Alert 

See Video Link: 

www.youtube.com/watch?v=LOm81obvaDE

 

Filter Auto 

Clean 

(iVac Only) 

Illuminated 

FULLY 

  

Flashing 

Slowly 

 

None 

 Unit in operation & filters are 

scheduled to be cleaned the next time 

unit is shut off for more than 5 

seconds 

 

  

 

 

Flashing 

Quickly 

 

None 

Unit is OFF, filter being cleaned 

 

 Illuminated 

FULLY 

  

Illuminated 

FULLY 

 

None 

Unit in operation. 

ALERT, filter cleaning motor not 

operating at optimum 

Replace Filter Cleaning motor 

 Fading 

IN-OUT 

  

OFF 

 

 

None 

Unit is in Constant AUTO Cleaning Mode 

Vacuum Controlled By POWER Button On 

Control Panel 

 Unit Automatically  Shuts OFF 
Vaccum , Cleans & The ReStarts 

Vaccum 

 Fading 

   

Illuminated 

 

None 

Unit is in Constant AUTO Cleaning Mode 

 Unit Automatically  Shuts OFF 

Содержание Zenotec Air+

Страница 1: ...ZENOTEC Air Instructions for Use iVT16 912 120 volt iVT25 912 230 volt...

Страница 2: ...three pronged plug on the end of the cord Disconnect power prior to accessing unit when checking or replacing filters or servicing motor blower When servicing the motors be careful when touching the...

Страница 3: ...AYS CHECK SYSTEM VOLTAGE BEFORE PLUGGING INTO POWER SOURCE Warning This is a class A product In domestic environment this product may cause radio interference in which case the user may be required to...

Страница 4: ...p after a 3 second delay If applicable set the shut off delay in Zenotec control software to the shortest possible interval The iVac System has a 3 second delay that cannot be turned off Note When ope...

Страница 5: ...y 5 Mins 10 hrs of life left in brushes Unit Will SHUT DOWN In 10 Hours to prevent motor damage Flashing Quickly Illuminated FULLY Beep Every Second Motor Brush Life Expired Unit Shut Down Replace ALL...

Страница 6: ...IN OUT FULLY Vacuum Controlled By Remote or mc2 Vaccum Cleans The ReStarts Vaccum...

Страница 7: ...r spare parts and replace immediately 10 Filter Replacement Guide Filter requires replacement if appropriate light on control panel illuminates and beeper sounds for 2 seconds every 4 hours Filter rep...

Страница 8: ...wer section door TURBINE BRUSHES are visible once door is removed RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTOR BRUSHES If Motor Brushes are replaced WHILE BRUSH REPLACEMENT LIGHT was FLAS...

Страница 9: ...hantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage No person firm or corporation is authorised to assume for QUATRO any other lia...

Страница 10: ...s This ensures that patients can trust in the quality of their dentures and our partners in dental practices and laboratories can continue with confidence on the path to digitalisation and greater com...

Отзывы: