11- MOTOR SERVICE 

 

BLOWER MAINTENANCE, CHANGING BRUSHES 

This unit is also equipped with an Automatic Motor and Brush Optimization System.  To optimize motor life, motor brushes need to be monitored and replaced 
PRIOR TO BEING WORN RIGHT OWN TO THE BASE.  If brush is worn to the base, there is HIGH RISK of brush damaging the motor.  If this happens, you will 
require replacement of entire motor. 
To avoid this, QUATRO has developed an Automatic Motor and Brush Optimization System.  When “Service Motors” light FLASHES continuously, it is time 
replace brushes (wear factor is down to 10-20% life remaining).  As soon as “Service Motors” light starts flashing continuously order new brushes right away. 
When Automatic Motor and Brush Optimization System estimates motor brushes have been worn to dangerous level, 

UNIT WILL SHUT DOWN. 

BRUSHES MUST BE REPLACED AT THIS POINT, UNIT WILL NOT OPERATE FOR FEAR OF MOTOR DAMAGE. 
 

To optimize and ensure longest brush life, AFTER REPLACEMENT, START motor right away, 

speed will automatically default to LOW

Operating the motor at Low speed for 15 minutes will “break-in” the new brushes, optimizing and prolong their life. 

 

WARNING:  Switch unit off and unplug power cord from wall before servicing the blower. 

 

 

 

 

 

 

  Figure 

1   

 

 

 

Figure 2   

 

 

 

Figure 3 

 

1) Using a phillips screwdriver, unscrew the 2 screws holding down each of 2 gold colored brush casings (see Figure 1) 
2) Lift gold colored tab and lift/pull out each brush (

Figure 2 shows right brush removed

3) Replace each brush onto turbine motor, screwing down the phillips screws over tab. 

 

YOU DO NOT HAVE TO REMOVE TURBINE FROM UNIT TO CHANGE BRUSHES!  

   

 

 

 

 
To access motor, remove blower section door.  TURBINE & BRUSHES are visible once door is removed. 

RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTOR BRUSHES 

If Motor Brushes are replaced 
WHILE BRUSH REPLACEMENT LIGHT was FLASHING 

If Motor Brushes are replaced 
AFTER MICROPROCESSOR HAS SHUT UNIT DOWN 
(Brush Replacement Light is FULL ON, not flashing) 

  Unplug POWER to unit 

  Replace Motor Brushes 

  Close motor access door 

  Plug power back to the unit 

  Unplug POWER to unit 

  Replace Motor Brushes 

  Close motor access door 

  Plug power back to the unit 

  When you Press “System ON”, 

MOTOR WILL START

 

 

BUT “Service Motor(s) Light will continue flashing

 

  When you Press “POWER ON”, 

MOTOR WILL NOT START 

 BUT “Service Motor(s) Light will continue flashing

 

  Press & HOLD 

SPD UP & DN

 at the same time until unit BEEPS (5 seconds) 

  “Service Motor(s)”, “Service Filter(s)” & “AutoCleaning Filter” Lights will be Dimming 

In-Out or flashing 

  

Press 

SPD UP or DN

 until “Service Motor(s)” light is FLASHING 

  Press and HOLD 

POWER

 button, “Service Motor” light will go OFF 

  DO NOT PRESS ANY OTHER BUTTON, after 20 seconds, speed will default to 

LOW SPEED to  break new brushes in (to prolong brush life) 

 

IT IS ADVISED TO LET MOTOR OPERATE AT LOW SPEED FOR 15 MINUTES 

 Press 

HOLD 

SPD UP & DN

 at the same time until unit BEEPS (5 seconds) 

  “Service Motor(s)” Light will be FLASHING, & “Service Filter(s)” & “AutoCleaning Filter” 

Lights will Dim In-Out 

  Press & HOLD 

POWER

 button, “Service Motor” light will go OFF 

  DO NOT PRESS ANY OTHER BUTTON, after 20 seconds, speed will default to LOW 

SPEED to  break new brushes in (to prolong brush life) 

IT IS ADVISED TO LET MOTOR OPERATE AT LOW SPEED FOR 15 MINUTES 

12- TROUBLESHOOTING GUIDE 

Symptoms Possible 

Cause 

Suggested 

Solution 

Motor(s) located in the 

rear of unit 

Motor(s) located in the rear of unit 

iVAC models have 1 motor 

iVAC TWIN models have 2 motors 

Main Filter Section 

Dust Collection 

Chamber 

Содержание Zenotec Air+

Страница 1: ...ZENOTEC Air Instructions for Use iVT16 912 120 volt iVT25 912 230 volt...

Страница 2: ...three pronged plug on the end of the cord Disconnect power prior to accessing unit when checking or replacing filters or servicing motor blower When servicing the motors be careful when touching the...

Страница 3: ...AYS CHECK SYSTEM VOLTAGE BEFORE PLUGGING INTO POWER SOURCE Warning This is a class A product In domestic environment this product may cause radio interference in which case the user may be required to...

Страница 4: ...p after a 3 second delay If applicable set the shut off delay in Zenotec control software to the shortest possible interval The iVac System has a 3 second delay that cannot be turned off Note When ope...

Страница 5: ...y 5 Mins 10 hrs of life left in brushes Unit Will SHUT DOWN In 10 Hours to prevent motor damage Flashing Quickly Illuminated FULLY Beep Every Second Motor Brush Life Expired Unit Shut Down Replace ALL...

Страница 6: ...IN OUT FULLY Vacuum Controlled By Remote or mc2 Vaccum Cleans The ReStarts Vaccum...

Страница 7: ...r spare parts and replace immediately 10 Filter Replacement Guide Filter requires replacement if appropriate light on control panel illuminates and beeper sounds for 2 seconds every 4 hours Filter rep...

Страница 8: ...wer section door TURBINE BRUSHES are visible once door is removed RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTOR BRUSHES If Motor Brushes are replaced WHILE BRUSH REPLACEMENT LIGHT was FLAS...

Страница 9: ...hantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage No person firm or corporation is authorised to assume for QUATRO any other lia...

Страница 10: ...s This ensures that patients can trust in the quality of their dentures and our partners in dental practices and laboratories can continue with confidence on the path to digitalisation and greater com...

Отзывы: