5
| Router Design
24
Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016
5.9.2
RS232-RS485/422 interface
These interfaces are physically connected on five-pin and four-pin terminal block connectors. The insula-
tion strength is up to 2.5 kV.
Attention!
Connectors are not isolated from each other!
Version with RS232-RS485/422 interface
Connection of RS232 connector:
Pin
Signal Description
Direction
1
CTS
Clear To Send
Output
2
RTS
Request To Send
Input
3
GND
Signal ground*
—
4
RXD
Receive Data
Input
5
TXD
Transmit Data
Output
RS232 connector
*Both connectors (RS232 and RS485/422) have common ground
.
Connection of RS485 connector:
Pin
Signal Description
Direction
1
TxRx+ RS485 B (+)
Input/Output
2
TxRx-
RS485 A (-)
Input/Output
3
TxRx+ RS485 B (+)
Input/Output
4
TxRx-
RS485 A (-)
Input/Output
Connection of RS422 connector:
Pin
Signal Description
Direction
1
RxD+
RS422 (+)
Output
2
RxD-
RS422 (-)
Output
3
TxD+
RS422 (+)
Input
4
TxD-
RS422 (-)
Input
RS485/422 connector
ATTENTION