2.20.8 Process data from module to PLC (inputs)
5 words* are transferred to the PLC. Words 1-4 always contain the current counter
content.
*Word 3 and Word 4 are not transferred when the data width is set to 3. Word 5 is
then transferred as word 3.
Word 5: Status of inputs/outputs
Bit values
Description
Xxxx xxxx xxxx xxx0 b
Status of COUNT+ for counter 1/16 or 1/32 is 0 (0 V)
Xxxx xxxx xxxx xxx1 b
Status of COUNT+ for counter 1/16 or 1/32 is 1 (24 V)
Xxxx xxxx xxxx xx0x b
Status of COUNT+ for counter 2/16 is 0 (0 V)
Xxxx xxxx xxxx xx1x b
Status of COUNT+ for counter 2/16 is 1 (24 V)
Xxxx xxxx xxxx x0xx b
Status of COUNT-/DELETE/DIRECTION for counter 1/16 or 1/32 is 0 (0 V)
Xxxx xxxx xxxx x1xx b
Status of COUNT-/DELETE/DIRECTION for counter 1/16 or 1/32 is 1 (24 V)
Xxxx xxxx xxxx 0xxx b
Status of COUNT-/DELETE/DIRECTION for counter 2/16 is 0 (0 V)
Xxxx xxxx xxxx 1xxx b
Status of COUNT-/DELETE/DIRECTION for counter 2/16 is 1 (24 V)
xxxx xxxx xxx0 xxxx b
Status of GATE for counter 1/16 or 1/32 is 0 (0 V)
xxxx xxxx xxx1 xxxx b
Status of GATE for counter 1/16 or 1/32 is 1 (24 V)
xxxx xxxx xx0x xxxx b
Status of GATE for counter 2/16 is 0 (0 V)
xxxx xxxx xx1x xxxx b
Status of GATE for counter 2/16 is 1 (24 V)
xxxx xxxx x0xx xxxx b
Status of threshold comparison 1 for counter 1/16 or 1/32 is 0 (0 V)
xxxx xxxx x1xx xxxx b
Status of threshold comparison 1 for counter 1/16 or 1/32 is 1 (24 V)
xxxx xxxx 0xxx xxxx b
Status of threshold 1 for counter 2/16 or threshold 2 for counter 1/32 is 0 (0 V)
xxxx xxxx 1xxx xxxx b
Status of threshold 1 for counter 2/16 or threshold 2 for counter 1/32 is 1 (24 V)
xxxx xxx0 xxxx xxxx b
Status of COUNT+ for counter 3/16 or 2/32 is 0 (0 V)
xxxx xxx1 xxxx xxxx b
Status of COUNT+ for counter 3/16 or 2/32 is 1 (24 V)
xxxx xx0x xxxx xxxx b
Status of COUNT+ for counter 4/16 is 0 (0 V)
xxxx xx1x xxxx xxxx b
Status of COUNT+ for counter 4/16 is 1 (24 V)
xxxx x0xx xxxx xxxx b
Status of COUNT-/DELETE/DIRECTION for counter 3/16 or 2/32 is 0 (0 V)
xxxx x1xx xxxx xxxx b
Status of COUNT-/DELETE/DIRECTION for counter 3/16 or 2/32 is 1 (24 V)
Xxxx 0xxx xxxx xxxx b
Status of COUNT-/DELETE/DIRECTION for counter 4/16 is 0 (0 V)
Xxxx 1xxx xxxx xxxx b
Status of COUNT-/DELETE/DIRECTION for counter 4/16 is 1 (24 V)
xxx0 xxxx xxxx xxxx b
Status of GATE for counter 3/16 or 2/32 is 0 (0 V)
xxx1 xxxx xxxx xxxx b
Status of GATE for counter 3/16 or 2/32 is 1 (24 V)
xx0x xxxx xxxx xxxx b
Status of GATE for counter 4/16 is 0 (0 V)
xx1x xxxx xxxx xxxx b
Status of GATE for counter 4/16 is 1 (24 V)
x0xx xxxx xxxx xxxx b
Status of threshold comparison for counter 3/16 or 2/32 is 0
(0 V)
x1xx xxxx xxxx xxxx b
Status of threshold comparison for counter 3/16 or 2/32 is 1
(24 V)
0xxx xxxx xxxx xxxx b
Status of threshold 1 for counter 4/16 or threshold 2 for counter 2/32 is 0 (0 V)
1xxx xxxx xxxx xxxx b
Status of threshold 1 for counter 4/16 or threshold 2 for counter 2/32 is 1 (24 V)
x: Any bit value b: Binary display