Appendix D: Warnings and Notices 

 

  Use only hard drives that are in perfect condition.  Avoid using drives that have ever developed 

bad sectors during previous usage.  This could lead to possible device failure or loss of data.   

  The RTX supports SATA hard drives of various specifications and different capacities.  However, 

we recommend using drives of the same brand and type for optimal performance.  If drives of 
different capacities are used in a RAID, the capacity of the smallest drive will determine how much 
of each drive is used.  The additional capacity on the larger drives will not be used by the RAID.   

  RAID level 0 will allow you to use the full combined capacity of the drives, and offers the best data 

transfer speeds.  However, RAID 0 offers no protection for the data.  If one drive fails in a RAID 0, 
the data on all of the drives is irretrievably lost.  Before creating a RAID, investigate the various 
RAID types and choose the one that is best for your needs.   

  Always back up data before switching RAID types.  You must reformat your drives afterwards. 

  Before starting any type of hardware installation, please ensure that all power switches have been 

turned off and all power cords have been disconnected to prevent personal injury and damage to 
the hardware. 

  To avoid overheating, RTX should be operated in a well-ventilated area and in such a way that 

sufficient airflow is maintained across the controller chips. 

  Static electricity can damage electronic components such as the exposed circuitry on hard drives. 

When swapping hard drives in the RTX, take precautions to guard against such damage: 

o

 

Work in a static-free environment 

o

 

Wear a grounded anti-static wrist strap 

o

 

Store uninstalled components in anti-static protective bags 

o

 

Handle the drives by their edges and avoid touching the exposed circuitry 

 

Appendix E: Frequently Asked Questions (FAQ) 

 

Q. 

I created one volume, but my computer sees two of them.  Why?   

A. 

There may be two LUNs assigned to that volume.  To check this, use the GUI.  Navigate to 

Volume 

Config

 and then 

Logical Unit

.  If there are two LUNs for the same volume, click the checkbox for one of 

them and click on “detach.”  Note: You may still see two volumes until you restart your computer.  

 

Q: 

I've hooked up the LAN GUI port to my DHCP-enabled network, but the LCD displays an IP address 

that is not on my network and I cannot connect to the GUI control panel using that IP address in my web 
browser.  

A: 

This may occur if you plugged in the LAN GUI after the RTX has already started up and initialized, or if 

you previously configured the RTX for a static network or direct connection.  The solution is to use the 
LCD interface to obtain a DHCP address.  Press ENT, then use the up or down arrows to scroll to the 
option 

Change IP config

.  Press ENT.  The screen will say 

DHCP

.  Press ENT then press the up arrow 

to select 

Yes

.  Press ENT.  The RTX will now attempt to acquire a DHCP address.  This new address will 

be displayed on the main screen of the LCD.  

 

Q. 

When I try to log on to the RTX-UR using the IP address under the iSCSI configuration menu nothing 

happens.  

A. 

Sometimes when you first set up the RTX-UR you'll need to reattach the LUN (Logical Unit Number) if 

it doesn't work the first time. 

 

Q: 

I’ve formatted the RTX’s drive, and my disk utility reports that a volume was successfully created, but I 

can’t find the volume or access it.   

A: 

Try restarting your computer.  Sometimes this is a necessary step before a new volume will become 

usable.   

Содержание RTX400-UR

Страница 1: ...RT X U R U s e r s M anu a l 1 RTX UR RTX400 UR RTX400H UR RTX600 UR RTX600H UR RTX800 UR ULTRA 320 SCSI to SATA Disk Subsystem User s Manual Revised July 29 2008...

Страница 2: ...ally be familiar and have some experience with RAID planning and data storage operations However this manual will provide instructions and education for those who have little or no experience in RAID...

Страница 3: ...o a static network 10 4 2 6 If you are connected directly to a computer 10 Chapter 5 Using the GUI 11 5 1 GUI indicators 11 5 2 Overview of GUI architecture 12 5 3 Quick Install 12 5 4 System Config 1...

Страница 4: ...Set up of RAID 25 5 9 Connecting to your Computer 25 Chapter 6 Formatting new volume s 26 Appendix A Certification list 27 Appendix B Event notifications 28 Appendix C Working with Volumes over 2TB i...

Страница 5: ...RAID 3 5 Reads are higher than a single disk Writes are similar to a single disk 0 1 Also known as Block Interleaved Parity Data and parity information is subdivided and distributed across all disks P...

Страница 6: ...f your new product This will help you to better understand the remaining instructions RTX400 UR RTX400H UR RTX600H UR Accessories Quantity SCSI Cable 1 RS 232 Configuration Cable 1 Power Cable 1 Packe...

Страница 7: ...hind it The drive is inserted with the label up and the SATA connection on the drive inserted first With the RTX400 RTX600H you can lock the bay for additional security but make sure to unlock it befo...

Страница 8: ...r c Connect the power cable to the rear of the RTX and to a grounded electrical outlet d Turn on the RTX unit s power using the switch on the rear panel 4 2 Use the LCD to configure the LAN GUI port R...

Страница 9: ...2 168 0 1 Default subnet mask 255 255 255 0 Default gateway 192 168 0 254 4 2 3 RTX UR LCD Menu Diagram Use the following chart for reference when following the instructions in 5 2 4 through 5 2 7 for...

Страница 10: ...rectly to a computer The instructions are similar to those for a static network see 5 2 2 except that your computer will not have the IP address assigned if it s not a part of a network Since the RTX...

Страница 11: ...prompted for a user name and password The user name is admin and the default password is 1234 5 1 GUI indicators The top right hand corner of the GUI window displays several indicators RAID light Gree...

Страница 12: ...n Rename Migrate User Data Volume Create Delete Attach LUN Snapshot More information Rename Extend Set read write mode Set priority Resize Snapshot space Auto Snapshot Cache Volume Create Delete More...

Страница 13: ...UR individual serial number Note that this serial number is different from the one on the outside of the product and is not the one that should be used to contact technical support To change the syste...

Страница 14: ...the administrative password used to access the GUI Recall that the default user name and password is admin 1234 To change the password enter the old password in the first field then type the new pass...

Страница 15: ...rk time provider can be used to sync the RTX UR s time information with that of a standardized server To use an NTP click the NTP check box then input the server information in the server field Click...

Страница 16: ...ing server or computer then click confirm Note The receiving server must be configured to receive SMNP messages For more information on SMNP you may wish to consult the third party website http www te...

Страница 17: ...d in the GUI Use the checkboxes to configure how the information is displayed Click the Download button to download the entire event log as a text file Click the Clear button to clear the entire event...

Страница 18: ...cache memory size as defined or configured by user LUN is a SCSI protocol that the computer uses to distinguish and access SCSI devices 5 5 1 Physical Disk Click the Physical Disk option to view and m...

Страница 19: ...ndown If auto spindown is enabled after a set amount of time 30 seconds 1 minute 5 minutes or 30 minutes of inactivity RTX UR will spin down the hard drives to save power The drives will be spun up ag...

Страница 20: ...he VG not yet assigned to a UDV PD The number of drives in the VG UDV The number of UDVs that have been created as part of the VG Status The status of the VG Possible states are Online and Fail 1 Disp...

Страница 21: ...activities rebuild initialization versus priority given to file transfers High priority will result in slower file transfers during initialization but provide for faster initialization After selecting...

Страница 22: ...u must click on the button below the size of the global cache and enter a number lower than the maximum value then click Confirm This frees up space to create a new cache Now click Create enter the de...

Страница 23: ...s of a SCSI device The RTX UR is an SES compliant enclosure however in order to use manage RTX UR using SES you must have the appropriate software installed on your computer An example is SMART Monito...

Страница 24: ...rive at all times to detect if certain values have moved outside of a certain range The S M A R T option allows you to view the S M A R T status of all of your hard drives 5 7 Maintenance The maintena...

Страница 25: ...o include in the Volume Group and press the Free Disk button c Click on Select PD Select all the hard drives you wish to put into the new RAID You ll need to confirm your choice d Next go to User Data...

Страница 26: ...r example Disk Utility for Mac OS X or Disk Management for Windows Consult your computer s operating manual for details Usage with Macintosh computers Mounting and Ejecting Volumes When you connect th...

Страница 27: ...Model Intel PWLA8490MT Gigabit 1 port TCP IP offload Intel PWLA8492MT Gigabit 2 port TCP IP offload Intel PWLA8494MT Gigabit 4 port TCP IP offload SATA Hard Drive Vendor Model Hitachi Deskstar 7K250 H...

Страница 28: ...block error Warning HDD failure Error Disk slot is failed Warning Channel error Error Disk slot IO incomplete SES Events Level Type Description Info SES load conf OK Info SES configuration has been l...

Страница 29: ...Info System has been initialized OK Error System Init Failed Error System could be initialized in the last boot up LVM Events Level Type Description Info VG Created OK Info VG name has been created Wa...

Страница 30: ...DV name is set to high priority Info Mid Priority UDV Info UDV name is set to mid priority Info Low Priority UDV Info UDV name is set to low priority Appendix C Working with Volumes over 2TB in size A...

Страница 31: ...k in a static free environment o Wear a grounded anti static wrist strap o Store uninstalled components in anti static protective bags o Handle the drives by their edges and avoid touching the exposed...

Страница 32: ...rives 30lbs with drives RTX800 UR 23lbs sans drives 33lbs with drives Dimensions 177mm W x 270mm D x 274mm H RTX400 UR RTX400H UR RTX600 UR 177mm W x 270mm D x 361mm H RTX600H UR and RTX800 UR Warrant...

Отзывы: