![WiebeTech RTX400-UR Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/wiebetech/rtx400-ur/rtx400-ur_user-manual_979526016.webp)
WiebeTech LLC
R T X - U R U s e r ’ s M a n u a l
- 16 -
5.4.7 Mail
RTX-UR can be configured to send email to up to 3 addresses when events, warnings, and errors occur.
Contact your IT administrator to set up an email address for RTX-UR and to input the proper SMTP
settings.
5.4.8 Simple Network Management Protocol (SMNP)
SNMP can be configured to send trap messages to up to three different addresses on the network. To
add an address, simply enter the IP address of the receiving server or computer, then click confirm. Note:
The receiving server must be configured to receive SMNP messages.
For more information on SMNP, you may wish to consult the third party website:
http://www.tech-
faq.com/snmp.shtml
5.4.9 System Log Server
The System Log Server option allows configuration for error, warning, and information reporting via a
certain port on the server. Enter the server IP in the first line and the port used in the second line (default
514). The facility can be changed between User and Local1 through Local7 using the dropdown box.
Select the check boxes for Info, Error, and Warning that pertain to the information that you want to be
reported.