Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
02.08.2011
Working Instructions WIDOS 4900 CNC 3.5
Page 32 of 68
Display:
2. line:
please read addit.
pipe code (2nd pipe)
Read with bar code reader
Simultaneously pres all buttons <+ / - / Enter>.
Then manually enter barcode of 2
nd
pipe: Select first digit with <+/-> and
jump to the next digit with <Enter>.
Display:
2. line:
Traceability 2:
RB PE80 160 9.1
The pipe data is displayed
in case of different pipe data, an error message appears:
Display:
2. line:
error: not possible
to weld those pipes
Confirm the error message by pressing button <Enter>
If the length of pipe is entered additional, disapears:
Display:
2. line:
length of 1. pipe
+000.00 mm
Enter the length of the last (read in) barcode pipe 1 up to the joint by buttons
<+ / - / Enter>
Press button <Start>
Display:
2. line:
length of 2. pipe
+000.00 mm
Enter the length of the last (read in) barcode pipe 2 up to the joint by buttons
<+ / - / Enter>
Press button <Start>
Display:
2. line:
mat. diam wall temp
PE80 225 20.5 206°
The welding parameters are displayed
next menu by pressing <Start> button
Continue as described in chapter: 5.11 welding process