Check the heater thoroughly for any signs of damage, do not use if damage was found. 

Ensure adequate ven�la�on and check surrounding area is free from combus�ble materials, moisture or 

dust. Observe clearance distance from walls and combus�ble objects/materials. Minimum clearance: heat 

outlet (front): 2.5m, air inlet (rear): 2m, top: 2m, sides: 2m. Do not posi�on this appliance on flammable 

surfaces such as wood. 

Before connec�ng the gas supply, check the outlet pressure of the gas regulator and gas hose according 

to specifica�on in sec�on 7 of this manual. Ensure the area is flame free to prevent risk of explosion.

Locate the heater on stable, level surface.

Connec�ng gas cylinder:

1. Connect the BS 3016 approved gas regulator to the BS 3212 approved hose.

2. Screw fasten the has regulator to the cylinder valve, follow instruc�ons supplied with regulator and/or  

    gas cylinder.

3. Connect the other end of the hose to the gas inlet connector on the heater (5).

4. Open the gas supply on the cylinder and perform gas leak test on both ends of the hose. Follow  

 

     instruc�ons in sec�on (6). Close the gas supply on the cylinder if no leak was detected.

Star�ng the heater:

5. Plug in the heater to suitable 220-240V mains power supply. Press the ON/OFF power switch (9) to ON 

posi�on.

6. Open the gas supply valve on the gas cylinder. 

7. Use the right hand to push the aluminium handspike of the flameout protector (6) and keep for 10 

seconds, then use the le� hand to press the igniter bu�on for igni�on. A�er the gas ignites keep on 

pressing the handspike for another 10 seconds then release the right hand and the gas will burn 

con�nuously. 

8. Turn the adjustment knob to regulate the flame length and make it comply with the corresponding 

heat input.

9. Repeat the above steps when the machine runs out of gas and a new full cylinder is to be replaced. 

7. Gas Leak Test

8. Assembly and Operation Instructions

-6-

This must be carried out in a well ven�lated area, free from any open flame or other sources of igni�on. 

With the regulator connected to the cylinder, slowly turn on the regulator and proceed as follows:

1. Brush all hose connec�ons including pipe connec�ons to the gas valve, regulator connec�on to the 

bo�le and gas bo�le valve with a 50:50 solu�on of soap and water.

2. A stream of bubbles forming is an indica�on of a leak. If a leak is found, turn off the valve on the 

regulator, disconnect the regulator from the gas bo�le and remove the gas bo�le to a cool, outdoor 

well-ven�lated area. 

DO NOT USE THE HEATER IF A LEAK IS FOUND.

DO NOT USE A NAKED FLAMED FOR LEAK TESTING.

DO NOT OPERATE ANY ELECTRICAL EQUIPMENT IN THE PRESENCE OF A GAS LEAK.

Содержание IHEAT1

Страница 1: ...ng and using this ar cle Retain them for future reference and if you are passing this product to a third party always make sure this documenta on is included Gas Space Heater Model IHEAT1 IHEAT2 IHEAT...

Страница 2: ...he appliance or on the packaging 1 Explanation of symbols 2 Intended Use This appliance is designed as an auxiliary temporary hea ng for non domes c indoor spaces It must be used in well ven lated spa...

Страница 3: ...alist To avoid danger faulty power cords must only be replaced by the manufacturer customer service or a similarly quali ed person using an equivalent cable Switch o the appliance and always disconnec...

Страница 4: ...verhea ng may cause re The appliance should never be poin ng towards the gas cylinder This heater is not to be used for hea ng habitable areas of domes c premises for use in public buildings refer to...

Страница 5: ...on prevent the gas leakage and poten al carbon monoxide poisoning and re danger inducted by gas leakage A gas rate adjustment valve is installed in this product the heat input can be regulated to ful...

Страница 6: ...ly Press the ON OFF power switch 9 to ON posi on 6 Open the gas supply valve on the gas cylinder 7 Use the right hand to push the aluminium handspike of the ameout protector 6 and keep for 10 seconds...

Страница 7: ...obstruct the fan Straighten all fan blades Heater will not ignite No spark at igni on needle Spark cable disconnected Incorrect spark plug gap Distance between electrode and burner too large Any repa...

Страница 8: ...50Hz 30W 15kW 0 5bar 300m3 h 750m3 h 750m3 h 1 11kg h 2 2kg h 2 9kg h G30 I3B P IHEAT2 ZSG301 80W 30kW 1 5bar G30 I3B P IHEAT3 ZSG401 80W 40kW 1 5bar G30 I3B P Maximum allowed size of gas cylinder 10...

Страница 9: ...e every use You can prepare the test solu on ahead in the small garden sprayer Inspect the gas hose regularly for any signs of wear or damage Keep the heater in clean working order Inspect and clean t...

Страница 10: ...material In observance of European Direc ve 2012 19 EU on waste electric and electronic equipment and its implementa on in accordance with na onal law electric equipment that have reached the end of t...

Страница 11: ...11...

Страница 12: ...STRIAL HEATER V1 09 2018 Batch Number If problems are encountered with this appliance please quote your order number product code IHEAT1 IHEAT2 or IHEAT3 and below batch number every me you contact cu...

Отзывы: