5
FULLY INSET FITTING:
The fire can be inset up to the fixing flange as indicated in the diagram
.
IMPORTANT:
I
T
IS
IMPORTANT
TO
PROVIDE
SUFFICIENT
AIR
TO
THE
CAVITY
BEHIND
THE
APPLIANCE
. T
HE
RECOMMENDED
MINIMUM
IS
12,600
MM
2
.
T
HE
FIRE
MUST
BE
FITTED
WITH
A
MINIMUM
OF
50
MM
CLEARANCE
BETWEEN
THE
REAR
OF
THE
FIRE
AND
ANY
SOLID
WALL
.
Fitting the fire into a wall or aperture:
The fire should be fitted in an aperture cut to the size shown in the diagram; the cavity depth
should also be as shown – if the depth is less than shown the fire may not function correctly.
Installation of the fire:
Provision for a mains connection should be made at the rear of the aperture – If the appliance is to
be hard wired allow sufficient length of mains cable to enable removal of the appliance from the
aperture with the cable attached.
11. Fix the mains cable to the underside of the appliance
12. Slide the fire into the aperture
13. Check to ensure that the appliance is level.
14. Mark through the fixing holes in the outer flange and then remove the fire from the wall
aperture.
15. Drill the wall with a suitable sized drill and where necessary insert suitable fixings.
16. Connect the appliance to the mains socket.
17. Slide the complete fire into the aperture.
18. Fix the fire to the pre drilled holes with suitable fixings.
440
5
3
5
185
Floor
> 60
Cavity Minimum Dimensions
This Flange must
be on the outside
of the aperture